VENTS VUT 350 PB EC


Air handling unit in heat and sound-insulated casing. Air flow up to 410 m³/h. Heat recovery efficiency up to 91 %.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • ADDITIONAL TECHNICAL DATA
  • Dimensions
  • Designation key
  • ACCESSORIES
Description
Description
DESCRIPTION FANS
  • The VUT PB EC air handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extract.
  • The heat contained in the extract air is recuperated in the high-efficient plate, counter flow heat exchanger to warm up supply air.
  • The units are designed for energy efficient ventilation of cottages and flats and are compatible with round air ducts.
  • High efficient electronically commutated motors with external motor and impeller with backward curved blades.
  • Such motors are the most state-of-the art energy saving solution.
  • EC motors are featured with high performance and total speed controllable range.
  • High efficiency reaching 90% is the premium advantage of the electronically commutated motors.
CASING HEAT EXHANGERS  
  • Made of high-quality aluzink steel, internally lined with 40 mm mineral wool heat- and sound-insulating layer.
  • Counter-flow aluminum heat exchangers with high heat recovery efficiency.
  • The drain pan under the heat exchanger block ensures condensate removal in both horizontal and vertical positions.
  • In case of freezing danger determined by the temperature sensor, the supply fan is turned off for the period required for the heat exchanger defrosting.
  • The heat exchanger is easily removed for cleaning.
FILTER 
  • The built-in F7 panel filters provide supply air filtration.
  • The built-in G4 panel extract filters provide extract air filtration.
CONTROL AND AUTOMATION 
BYPASS  
  • The unit includes integrated automation.
  • The heat exchanger freezing protection operates as follows: In case of freezing danger determined by the temperature sensor the supply fan is turned off to let extract air warm up the heat exchanger. After freezing danger is no longer imminent, the unit reverts to the standard operation mode.
  • Delivery set includes a multifunctional control panel indication and a 10 m long signaling cable.
  • Units are equipped with a 100 % bypass, which can be opened if there is a need to cool down the ventilated area with cool intake air.
SENSOR CONTROL PANEL (A14)  
  • VUT 160 PB EC A14 and VUT 350 PB EC A14 units are equipped with A14 sensor control panel with LED indication and following functions:
    • Speed selection: Off, Low, Medium or High;
    • Manual opening and closing of the bypass damper;
    • Filter clogging control by motor hours;
    • Fault indication;
    • Control according to the optional duct humidity sensor HV2 feedback or according to an optional external sensor with NO contacts;
    • Ventilation system shutdown at signal from the fire alarm system;
  • VUT 160 PB EC A14 and VUT 350 PB EC A14 units can be connected to a PC by means of a USB cable. Special software gives following possibilities:
    • Software update of the unit;
    • Adjusting of the Off, Low, Medium or High speed modes from 0 to 100 % for supply and exhaust fans separately;
    • Adjustment of the humidity level and the speed activated by optional humidity sensor HV2;
    • Adjustment of the speed activated by the optional external relay;
    • Adjustment of the temperature of activation of freezing protection;
    • Adjustment of filter maintenance timer;
    • Monitoring of the maintenance timer, humidity level, external relay, and bypass;
    • Error code indication.

PU SENS 01 CONTROL PANEL (A11)   
  • VUT 160 PB EC A11 and VUT 350 PB EC A11 units are equipped with touch-screen LCD control panel PU SENS 01 with following functions:
    • Turning unit on/off;
    • Low-medium-high speed selection and adjustment from 0 up to 100% for supply and exhaust fans separately;
    • Manual or automatic opening/closing of the bypass for summer ventilation;
    • Timer;
    • Week scheduled;
    • Actuating external air dampers;
    • Indication, adjustment and maintaining set room or supply air temperature;
    • Control according to the optional duct humidity sensor HV1 feedback or according to the humidity sensor built in the control panel;
    • Filter clogging control by motor hours;
    • Ventilation system shutdown at signal from the fire alarm system;
    • Cooler connection possibility.

MOUNTING
  • Units can be mounted in two different ways:
    • Suspended to the ceiling;
    • Hanged in the wall with vertical position of flanges.
  • Access for the unit servicing and filter maintenance on the bottom panel side.
APPLICATION EXAMPLE  
Characteristics
Characteristics
Parameter VUT 350 PB EC
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power 170 W
Maximum unit current 1.3 A
Sound pressure level at 3 m distance 34 dBА
Maximum air capacity 410 m³/h
Heat recovery efficiency 80...91 %
Casing material aluzinc -
Insulation 40 mm mineral wool -
Filter: extract G4 -
Filter: supply * option F7 -
Connected air duct diameter 160 mm
Mass 70 kg
Heat exchanger type counter-flow -
Heat exchanger material aluminium -
SEC Class A -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Name
Brochure "VENTS VUT PB EC" (pdf 2.9Mb)
Download high quality image "VENTS VUT PB EC (ErP 2016, 2018)" (psd 3.77Mb)
Download image "VENTS VUT PB EC (ErP 2016, 2018)" for your website (png 252.15Kb)
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
User's manual "Sensor control panel PU SENS 01 A11/A19" (pdf 2.39Mb)
User's manual "VENTS VUT PB EC A11/A14" (pdf 4.17Mb)
User’s manual "Sensor control panel A14/A15" (pdf 1.16Mb)
User’s manual "Wireless control system A21" (pdf 2.44Mb)
Dimensions
Characteristics
Parameter Value Measurement unit
ADDITIONAL TECHNICAL DATA
ADDITIONAL TECHNICAL DATA
Sound power level, A - weighted Octave-frequency band [Hz] LpA, 3 m dBA LpA, 1 m dBA
Hz         Gen. 63 125 250 500 1000 2000 4000 8000
LwA to supply inlet dBA 60 46 54 58 50 46 40 40 31    
LwA to supply outlet dBA 63 52 58 60 54 46 40 41 35    
LwA to exhaust inlet dBA 61 47 54 58 50 47 41 41 32    
LwA to exhaust outlet dBA 63 51 58 59 56 46 40 41 35    
LwA to environment dBA 55 44 51 51 43 38 32 28 24 34 44
Dimensions
Dimensions

Designation key
Designation key
Series Rated air flow [m3/h] Mounting type Motor type Control
VENTS VUT 160; 250; 350 P - ceiling suspended B - bypass EC - synchronous electronically commutated motor A11 - touch-screen LCD control panel PU SENS 01
A14 - touch-screen panel with LED indication
ACCESSORIES
ACCESSORIES
Model Panel filter G4 Panel filter F7 Internal humidity sensor Internal humidity sensor External CO2 sensor External CO2 sensor with indication Outdoor humidity sensor Electric preheater U-trap kit Air damper Electric actuator
VUT 160 PB ЕС A11 SF
253x403x48
G4
SF
253x403x48
F7
HV1 - - - - NKP-125 SH-32 KRV 125 LF230
VUT 160 PB ЕС A14 - HV2 CO2-1 CO2-2 HR-S -
VUT 250 PB EC A11 HV1 - - - - NKP-125
VUT 250 PB EC A14 - HV2 CO2-1 CO2-2 HR-S -
VUT 350 PB EC A11 SF
253x603x48
G4
SF
253x603x48
F7
HV1 - - - - NKP-160 KRV 160
VUT 350 PB EC A14 - HV2 CO2-1 CO2-2 HR-S -