Unit of measurement | VUT 350 PB EC L A21 | |
Connected air duct size | mm | 160 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 170 |
Unit current | A | 1.3 |
Maximum airflow | m3/h | 410 |
Sound pressure level LpA at 3 m | dB(A) | 34 |
Heat recovery efficiency, max | % | 91 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Polystyrene |
Weight | kg | 70 |
Extract filter | - | G4 |
Supply filter | - | F7 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 80 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | VUT 350 PB EC L A21 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
80.5 | A+ | 42.4 | A+ | 16.6 | E | |
Type of ventilation unit | Bidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | Recuperative | |||||
Thermal efficiency of heat recovery (%) | 83 | |||||
Maximum flow rate (m3/h) | 370 | |||||
Electric power input (W) | 168 | |||||
Reference flow rate (m3/s) | 0.06 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.199 | |||||
Control typology | Local demand control | |||||
Maximum internal leakage rates (%) | 2.7 | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Sound power level (dB(A)) | 54 | |||||
Declared typology | RVU BVU | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
687 | 150 | 105 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
8334 | 4260 | 1926 |
Name | Photo | Description |
---|---|---|
Vents A22 | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A22 WiFi | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A25 | The control panel with a sensor display |
Name | Photo | Description |
---|---|---|
Vents HV2 | Humidity sensor | |
Vents CO2-1 | CO2 sensors | |
Vents CO2-2 | CO2 sensors | |
Vents HR-S | Electro-mechanical humidistats | |
Vents DPWC11200 | Humidity sensor |
Name | Photo | Description |
---|---|---|
Vents DPWQ30600 | VOC sensors | |
Vents DPWQ40200 | CO2 sensor |
Name | Photo | Description |
---|---|---|
Vents NKP 160-0,8-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-1,2-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-1,7-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-2,0-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKD 160-0,8-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 160-1,2-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 160-1,7-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 160-2,0-1 A21 V.2 | Duct heater for supply air post-heating with external control |
Name | Photo | Description |
---|---|---|
Vents SH-32 | The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems |
Name | Photo | Description |
---|---|---|
Vents KRV 160 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 | The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents SF 603x253x48 G4 | Panel filter G4 | |
Vents SF 603x253x48 F7 | F7 panel filter |