Unit of measurement | VUT 350 PE EC | |
Connected air duct size | mm | 160 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 200 |
Power of electrical preheater | W | 0 |
Power of electrical reheater | W | 1500 |
Unit current | A | 8.12 |
Maximum airflow | m3/h | 350 |
Sound pressure level LpA at 3 m | dB(A) | 48 |
Heat recovery efficiency, max | % | 90 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Aluminum |
Weight | kg | 67 |
Extract filter | - | G4 |
Supply filter | - | G4 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Trademark | Vents | |||||
Model | VUT 350 PE EC | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-77.2 | A+ | -39.3 | A | -14.9 | E | |
Type of ventilation unit | Bidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | Recuperative | |||||
Thermal efficiency of heat recovery (%) | 82 | |||||
Maximum flow rate (m3/h) | 340 | |||||
Electric power input (W) | 200 | |||||
Reference flow rate (m3/s) | 0.066 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.42 | |||||
Control typology | Local demand control | |||||
Maximum internal leakage rates (%) | 2.7 | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU BVU | |||||
Sound power level (dB(A)) | 68 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
804 | 267 | 222 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
8857 | 4528 | 2047 |
Name | Photo | Description |
---|---|---|
Vents SFK 208x236x27 G4 | G4 pocket filter | |
Vents SFK 208x236x27 F7 | F7 pocket filter | |
Vents SF 440x128x20 G4 | Panel filter G4 |
Name | Photo | Description |
---|---|---|
Vents SR 160/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 160/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 160/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 160/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 160/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 160 | Spring-loaded backdraft damper for round ducts | |
Vents KRV 160 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 | The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions | |
Vents Belimo TF230 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents C 160 | The clamps are designed for quick and reliable mounting and connection of various round ventilation system components. Clamps are made of stainless and galvanized steel band |