VENTS VUT 350 VB EC


Air handling unit in heat- and sound-insulated casing. Air flow up to 415 m³/h. Heat recovery efficiency up to 89 %.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional technical data
  • Designation key
  • Accessories
Description
Description
DESCRIPTION  
  • The air handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extract.
  • During operation the extract air heat is transferred to the supply air stream by the highly efficient plate heat exchanger.
  • The units are designed for energy efficient ventilation of cottages and flats and are compatible with round air ducts.
FILTER FANS
  • Supply and exhaust airflows are purified through panel filters with filtering class G4 and F7, respectively.
  • Supply and exhaust airflows in the VUT/VUE 200 VB EC units are purified through G3 filters.
  • Supply airflows in the VUT/VUE 250 VB EC units are purified through G4 and F7 filters.
  • Exhaust airflows are purified through G4 filters.
  • The units are equipped with high-efficient EC motors with an external rotor and backward curved blades.
  • These state-of-the-art motors offer the very best in energy efficiency today.
  • The high efficiency (up to 90 %) is a definite advantage of EC motors.
HEAT EXCHANGER  
  • The VUT VB EC units are equipped with a counter-flow polystyrene heat exchanger.
  • In the cold season the extract air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses.
  • This can lead to formation of condensate that is collected in a special drain pan and discharged into the sewage system.
  • In the warm season the ambient air heat is transferred to the exhaust air stream.
  • This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load.

  • The VUE VB EC units are equipped with a counter-flow heat exchanger with an enthalpy membrane.
  • In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses from ventilation.
  • Consequently, it is the ambient air heat and moisture transferred to the exhaust air stream through the enthalpy membrane in the warm season.
  • This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load.

CASING BYPASS
  • Made of high-quality polymer coated steel, internally filled with a heat- and sound-insulated layer of mineral wool.
  • The VUT/VUE VB EC models are equipped with a bypass which can be opened if there is a need to cool down the ventilated area with cool intake air without heat recovery.
CONTROL AND AUTOMATION  
  • The VUT/VUE VB EC units may be equipped with two types of automation: A14 or A11.
  • The VUT/VUE VB EC A14 models have the A14 sensor control panel with LED indication.
  • The VUT/VUE VB EC A11 units have the LCD sensor control panel PU SENS 01.

  • Two ways of freeze protection are available:
 
  1. Supply fan stopping. The heat exchanger freeze protection operates as follows: in case of freezing danger determined by the temperature sensor, the supply fan is turned off to let extract air warm up the heat exchanger. After freezing danger is no longer imminent, the unit reverts to the standard operation mode.
  1. Pre-heating. When the outdoor air temperature drops below -3 ˚C, the heat exchanger freeze protection algorithm is activated by the NKP electric heater that heats the intake air.
  • The heater power is continuously adjusted by the automation system in order to prevent condensate freezing in the heat exchanger.
 
MOUNTING  
  • The units are designed for wall mounting.
  • The access for unit and filter maintenance is available from the front panel.
  • During mounting stage the front and the back panels can be reversed providing either left-handed or right-handed unit mounting.
UNIT DESIGN*  

The unit design differs depending on the model

APPLICATION OPTIONS  
Characteristics
Characteristics
Parameter VUT 350 VB EC
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power 170 W
Maximum air capacity 415 m³/h
RPM 3200 min-1
Sound pressure level at 3 m distance 28 dB(А)
Casing material painted steel -
Insulation 40 mm mineral wool -
Filter: extract G4 -
Filter: supply * option G4, F7 -
Connected air duct diameter 160 mm
Maximum unit current 1.3 A
Heat recovery efficiency 80...89 %
Heat exchanger type counter-flow -
Heat exchanger material polystyrene -
SEC Class A+ -
Weight 66 kg
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Name
User's manual "VENTS VUT V/ VB EC (A11)" (pdf 6.17Mb)
Brochure "VENTS VUT/VUE VB EC" (pdf 649.69Kb)
Download high quality image "VENTS VUT V/VB EC (ErP 2016, 2018)" (psd 3.93Mb)
Download image "VENTS VUT V/VB EC (ErP 2016, 2018)" for your website (png 268.91Kb)
User's manual "VENTS VUT V/ VB EC (A14)" (pdf 6.73Mb)
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
User's manual "VUT/VUE 200 V(B) EC, VUT/VUE 250 V(B) EC" (pdf 7.58Mb)
User's manual "VUT / VUE V(1)B EC (A19)" (pdf 5.35Mb)
Dimensions
Characteristics
VENTS VUT 350 VB EC
Parameter Value Measurement unit
∅D 159 mm
B 592 mm
H 675 mm
L 730 mm
Additional technical data
Additional technical data
A-weighted sound power level Gen. Octave-frequency band [Hz] LpA, 3 m [dBA] LpA, 1 m [dBA]
dBA 63 125 250 500 1000 2000 4000 8000
LwA to supply air inlet   56 50 46 53 45 39 34 36 32    
LwA to supply air outlet dBA 64 56 52 63 52 39 38 43 35    
LwA to exhaust air inlet dBA 56 52 46 53 45 38 34 36 31    
LwA to exhaust air outlet dBA 64 58 53 62 51 40 38 42 33    
LwA to environment dBA 49 45 40 44 38 33 29 27 22 28 38

Calculation of air temperature downstream of the heat exchanger:

t = toutd + khr * (textr - toutd) / 100,

where
toutd - outdoor air temperature [°C]
textr - extract air temperature [°C]
khr - heat exchanger efficiency (according to the diagram) [%]

Designation key
Designation key
Series Rated air flow [m3/h] Spigot orientation Casing design Bypass Motor type Control
VUT: ventilation with heat recovery;
VUE: ventilation with energy recovery
160; 200; 250; 300; 350; 550 V: vertical _: default value;
1: casing modification;
2: 20 mm insulation
_: without a bypass;
B: with a bypass
ЕС: synchronous electronically commutated motor А11: PU SENS 01 sensor LCD control panel;
А14: sensor control panel with LED indication
Accessories
Accessories
Model Panel filter G3 Panel filter G4 Panel filter F7 Built-in humidity sensor Outdoor CO2 sensor with indication Outdoor CO2 sensor Outdoor humidity sensor Kitchen hood Electric heater for preheating U-trap kit Air damper Electric actuator Summer block
 
VUT 160 V ЕС A14   SF 285х195х10 G4 SF 285х195х10 F7 - CO2-1 CO2-2 HR-S KH-1 - SH-32 KRV 125 LF230 VL С6 366/285
VUT 160 V ЕС A11 HV1 - - - - NKP-125
VUE 160 V ЕС A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 160 V ЕС A11 HV1 - - - - NKP-125
VUT 160 VB ЕС A14 - CO2-1 CO2-2 HR-S KH-1 - -
VUT 160 VB ЕС A11 HV1 - - - - NKP-125
VUE 160 VB ЕС A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 160 VB ЕС A11 HV1 - - - - NKP-125
VUT 160 V1 ЕС A14 - CO2-1 CO2-2 HR-S KH-1 - VL C6 366/285
VUT 160 V1 ЕС A11 HV1 - - - - NKP-125
VUE 160 V1 ЕС A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 160 V1 ЕС A11 HV1 - - - - NKP-125
VUT 160 V1B ЕС A14 - CO2-1 CO2-2 HR-S KH-1 - -
VUT 160 V1B ЕС A11 HV1 - - - - NKP-125
VUE 160 V1B ЕС A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 160 V1B ЕС A11 HV1 - - - - NKP-125
VUT 200 V EC A14 SF 264х195х18 G3     - CO2-1 CO2-2 HR-S KH-1 - VL C6 366/240
VUT 200 V EC A11 HV1 - - - - NKP-125
VUT 200 VB EC A14 - CO2-1 CO2-2 HR-S KH-1 - -
VUT 200 VB EC A11 HV1 - - - - NKP-125
VUE 200 V EC A14 - CO2-1 CO2-2 HR-S KH-1 - VL C6 366/240
VUE 200 V EC A11 HV1 - - - - NKP-125
VUE 200 VB EC A14 - CO2-1 CO2-2 HR-S KH-1 - -
VUE 200 VB EC A11 HV1 - - - - NKP-125
VUT 250 V EC A14   SF 200х417х18 G4 SF 200х417х18 F7 - CO2-1 CO2-2 HR-S KH-1 - KRV 160 VL C6 366/384
VUT 250 V EC A11 HV1 - - - - NKP-160
VUT 250 VB EC A14 - CO2-1 CO2-2 HR-S KH-1 - -
VUT 250 VB EC A11 HV1 - - - - NKP-160
VUE 250 V EC A14 - CO2-1 CO2-2 HR-S KH-1 - VL C6 366/384
VUE 250 V EC A11 HV1 - - - - NKP-160
VUE 250 VB EC A14 - CO2-1 CO2-2 HR-S KH-1 - -
VUE 250 VB EC A11 HV1 - - - - NKP-160
VUT 300 V2B ЕС A14   SF 400х196х40 G4 SF 400х196х40 F7 - CO2-1 CO2-2 HR-S KH-1 -
VUT 300 V2B ЕС A11 HV1 - - - - NKP-160
VUE 300 V2B ЕС A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 300 V2B ЕС A11 HV1 - - - - NKP-160
VUT 350 V1B ЕС A14   SF 384х196х40 G4 SF 384х196х40 F7 - CO2-1 CO2-2 HR-S KH-1 -
VUT 350 V1B ЕС A11 HV1 - - - - NKP-160
VUE 350 V1B ЕС A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 350 V1B ЕС A11 HV1 - - - - NKP-160
VUT 350 VB EC A14   SF 500х196х40 G4 SF 500х196х40 F7 - CO2-1 CO2-2 HR-S KH-1 -
VUT 350 VB EC A11 HV1 - - - - NKP-160
VUE 350 VB EC A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 350 VB EC A11 HV1 - - - - NKP-160
VUT 550 V2B ЕС A14 - CO2-1 CO2-2 HR-S KH-1 - KRV 200
VUT 550 V2B ЕС A11 HV1 - - - - NKP-200
VUE 550 V2B ЕС A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 550 V2B ЕС A11 HV1 - - - - NKP-200
VUT 550 VB ЕС A14   SF 630х198х40 G4 SF 630х198х40 F7 - CO2-1 CO2-2 HR-S KH-1 -
VUT 550 VB ЕС A11 HV1 - - - - NKP-200
VUE 550 VB ЕС A14 - CO2-1 CO2-2 HR-S KH-1 -
VUE 550 VB ЕС A11 HV1 - - - - NKP-200