Unit of measurement | VUT 350 VB EC A21 | |
Connected air duct size | mm | 160 |
Speed | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 178 |
Unit current | A | 1.4 |
Maximum airflow | m3/h | 450 |
Sound pressure level LpA at 3 m | dB(A) | 28 |
Heat recovery efficiency, max | % | 92 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Polystyrene |
Weight | kg | 64 |
Extract filter | - | G4 |
Supply filter | - | F7 (G4 optional) |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
ambient air temperature min | °С | 1 |
ambient air temperature max | °С | 40 |
ambient air humidity max | % | 60 |
Ingress protection rating | - | IP20 |
ØD | B | H | L |
---|---|---|---|
160 | 583 | 675 | 730 |
Name | Photo | Description |
---|---|---|
Vents A25 | The control panel with a sensor display | |
Vents A22 WiFi | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A22 | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Name | Photo | Description |
---|---|---|
Vents HV2 | Humidity sensor | |
Vents CO2-1 | CO2 sensors | |
Vents CO2-2 | CO2 sensors | |
Vents DPWC11200 | Humidity sensor | |
Vents HR-S | Electro-mechanical humidistats |
Name | Photo | Description |
---|---|---|
Vents DPWQ40200 | CO2 sensor | |
Vents DPWQ30600 | VOC sensors |
Name | Photo | Description |
---|---|---|
Vents NKP 160-0,8-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-1,2-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-1,7-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-2,0-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKD 160-0,8-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 160-1,2-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 160-1,7-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 160-2,0-1 A21 V.2 | Duct heater for supply air post-heating with external control |
Name | Photo | Description |
---|---|---|
Vents SH-32 | The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems |
Name | Photo | Description |
---|---|---|
Vents KRV 160 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 | The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents SF 500x196x40 F7 | F7 panel filter | |
Vents SF 500x196x40 G4 | Panel filter G4 |