Unit of measurement | VUT 400 HB EC A21 | |
Connected air duct size | mm | 200 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 289 |
Unit current | A | 2.1 |
Maximum airflow | m3/h | 540 |
Sound pressure level LpA at 3 m | dB(A) | 27 |
Heat recovery efficiency, max | % | 98 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Polystyrene |
Weight | kg | 74.8 |
Extract filter | - | G4 |
Supply filter | - | G4+F7 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 80 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | VUT 400 HB EC A21 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-81.6 | A+ | -42.5 | A+ | -17.5 | E | |
Type of ventilation unit | Bidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | Recuperative | |||||
Thermal efficiency of heat recovery (%) | 88 | |||||
Maximum flow rate (m3/h) | 480 | |||||
Electric power input (W) | 240 | |||||
Reference flow rate (m3/s) | 0.092 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.268 | |||||
Control typology | Local demand control | |||||
Maximum internal leakage rates (%) | 2.7 | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU BVU | |||||
Sound power level (dB(A)) | 41 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
724 | 187 | 142 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
9100 | 4652 | 2104 |
ØD | B | B1 | B2 | H | H1 | H2 | L | L1 |
---|---|---|---|---|---|---|---|---|
197 | 682 | 248 | 217 | 504 | 201 | 141 | 1094 | 1191 |
Name | Photo | Description |
---|---|---|
Vents A25 | The control panel with a sensor display | |
Vents A22 | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A22 WiFi | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Name | Photo | Description |
---|---|---|
Vents HV2 | Humidity sensor | |
Vents CO2-1 | CO2 sensors | |
Vents CO2-2 | CO2 sensors | |
Vents HR-S | Electro-mechanical humidistats | |
Vents DPWC11200 | Humidity sensor |
Name | Photo | Description |
---|---|---|
Vents DPWQ30600 | VOC sensors | |
Vents DPWQ40200 | CO2 sensor |
Name | Photo | Description |
---|---|---|
Vents NKD 200-1,2-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 200-1,7-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 200-2,0-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKP 200-1,2-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 200-1,7-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 200-2,0-1 A21 V.2 | Heater for heat exchanger freeze protection |
Name | Photo | Description |
---|---|---|
Vents SR 200/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 200/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 200/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 200/2000 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 200 | Spring-loaded backdraft damper for round ducts | |
Vents KRV 200 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents DN-2 | The drain pump provides extraction and discharge of condensate in ventilation systems |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 | The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions | |
Vents Belimo TF230 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents SF 600x205x48 G4 | Panel filter G4 | |
Vents SF 600x205x48 F7 | F7 panel filter |