Unit of measurement | VUT 600 PE EC | |
Connected air duct size | mm | 200 |
Speed | - | 1 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 270 |
Power of electrical preheater | W | 0 |
Power of electrical reheater | W | 2000 |
Unit current | A | 10.3 |
Maximum airflow | m3/h | 700 |
Sound pressure level LpA at 3 m | dB(A) | 53 |
Heat recovery efficiency, max | % | 90 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Aluminum |
Weight | kg | 75 |
Extract filter | - | G4 |
Supply filter | - | G4 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
ambient air temperature min | °С | 1 |
ambient air temperature max | °С | 40 |
∅D | B | B1 | B3 | B4 | H | H1 | L | L1 |
---|---|---|---|---|---|---|---|---|
200 | 827 | 712 | 294 | 345 | 280 | 120 | 1238 | 1291 |
Name | Photo | Description |
---|---|---|
Vents SFK 392x236x27 G4 | G4 pocket filter | |
Vents SFK 392x236x27 F7 | F7 pocket filter | |
Vents SF 782x128x20 G4 | Panel filter G4 |
Name | Photo | Description |
---|---|---|
Vents SR 200/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 200/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 200/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 200 | Spring-loaded backdraft damper for round ducts | |
Vents KRV 200 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 | The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions | |
Vents Belimo TF230 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents C 200 | The clamps are designed for quick and reliable mounting and connection of various round ventilation system components. Clamps are made of stainless and galvanized steel band |