| Unit of measurement | VUT 700 HBE EC A21 | |
| Connected air duct size | mm | 250 |
| Minimum supply voltage | V | 230 |
| Maximum supply voltage | V | 230 |
| Power supply frequency | Hz | 50/60 |
| Rated power | W | 336 |
| Power of electrical reheater | W | 3600 |
| Unit current | A | 18 |
| Maximum airflow | m3/h | 830 |
| Sound pressure level LpA at 3 m | dB(A) | 31 |
| Heat recovery efficiency, max | % | 98 |
| Heat exchanger type | - | Counter flow |
| Heat exchanger material | - | Polystyrene |
| Weight | kg | 108.4 |
| Extract filter | - | G4 |
| Supply filter | - | G4+F7 |
| Transported air temperature (max) | °С | 40 |
| Transported air temperature (min) | °С | -25 |
| Ambient air temperature min | °С | 1 |
| Ambient air temperature max | °С | 40 |
| Ambient air humidity max | % | 80 |
| Ingress protection rating | - | IP22 |
| Ingress protection rating of the drive | - | IP44 |
| Trademark | Vents | |||||
| Model | VUT 700 HBE EC A21 | |||||
| Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
| -80.8 | A+ | -42.2 | A+ | -17.5 | E | |
| Type of ventilation unit | Bidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | Recuperative | |||||
| Thermal efficiency of heat recovery (%) | 85 | |||||
| Maximum flow rate (m3/h) | 751 | |||||
| Electric power input (W) | 336 | |||||
| Reference flow rate (m3/s) | 0.143 | |||||
| Reference pressure difference (Pa) | 50 | |||||
| Specific power input (SPI) (W/(m3/h)) | 0.243 | |||||
| Control typology | Local demand control | |||||
| Maximum internal leakage rates (%) | 2.7 | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Sound power level (dB(A)) | 45 | |||||
| Declared typology | RVU BVU | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 710 | 173 | 128 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 8979 | 4590 | 2075 | ||||
| Name | Photo | Description |
|---|---|---|
| Vents A25 |
|
Touch screen control panel for controlling industrial and residential air handling units |
| Vents A22 |
|
Control panels for controlling industrial and residential air handling units |
| Vents A22 WiFi |
|
Control panels for controlling industrial and residential air handling units |
| Name | Photo | Description |
|---|---|---|
| Vents HV2 |
|
Humidity sensor |
| Vents CO2-1 |
|
CO2 sensors |
| Vents CO2-2 |
|
CO2 sensors |
| Vents HR-S |
|
Electro-mechanical humidistat |
| Name | Photo | Description |
|---|---|---|
| Vents NKP 250-1,2-1 A21 V.2 |
|
Inline heaters for heat exchanger frost protection |
| Vents NKP 250-2,0-1 A21 V.2 |
|
Inline heaters for heat exchanger frost protection |
| Vents NKP 250-3,0-1 A21 V.2 |
|
Inline heaters for heat exchanger frost protection |
| Name | Photo | Description |
|---|---|---|
| Vents SR 250/600 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 250/900 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 250/1200 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Name | Photo | Description |
|---|---|---|
| Vents KOM 250 |
|
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
| Vents KRV 250 |
|
Air dampers for automatic air flow control in round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents Belimo TF230 |
|
The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
| Name | Photo | Description |
|---|---|---|
| Vents SF 784x253x48 G4 |
|
Panel filter G4 |
| Vents SF 784x253x48 F7 |
|
F7 panel filter |