Vents VUTR 200 VEKS EC L A21

Vents VUTR 200 VEKS EC L A21 - Air handling units in a heat- and sound-insulated casing
New
Air handling units in a heat- and sound-insulated casing
  • Power of electrical reheater: 700 W
  • Maximum airflow: 270 m3/h
  • Sound pressure level LpA at 3 m: 33 dB(A)
  • Heat exchanger type: Rotary
  • Extract filter: G4
  • Supply filter: G4 (F7 опція)
  • Sound insulation
  • Motor type: EC
  • Bypass: Auto
  • Reheater: Built-in
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Steel
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUTR 200 VEKS EC L A21
Connected air duct size mm 125
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50
Rated power W 171
Power of electrical reheater W 700
Unit current A 4.31
Maximum airflow m3/h 270
Sound pressure level LpA at 3 m dB(A) 33
Heat recovery efficiency, max % 93
Heat exchanger type - Rotary
Heat exchanger material - Aluminum
Weight kg 53
Extract filter - G4
Supply filter - G4 (F7 опція)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents VUTR 200 VEKS EC L A21 45 240 2016
Trademark Vents
Model VUTR 200 VEKS EC L A21
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
85.6 A+ 41.1 A 15.6 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Regenerative
Thermal efficiency of heat recovery (%) 88
Maximum flow rate (m3/h) 240
Electric power input (W) 170
Reference flow rate (m3/s) 0.047
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.411
Control typology Local demand control
Maximum internal leakage rates (%) 3.3
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 45
Declared typology RVU BVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
217 869 217
The annual heating saved (AHS) (kWh/a) Cold Average Warm
9100 4652 2104
Datasheet
"VENTS VUTR 200 VK EC" product description 02-2024
936 Kb
Manual
"VENTS VUTR 200V(E)K EC" user’s manual 10-2024 (V273EN-01)
2.72 Mb
Image
VUTR 200 VEKS EC L A21 - image 1
373 Kb
H W W1 W2 L L1
746 596 408 173 326 338
Name Photo Description
Vents A25 A25 The control panel with a sensor display
Vents A22 A22 The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Vents A22 WiFi A22 WiFi The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Name Photo Description
Vents HR-S HR-S Electro-mechanical humidistats
Vents CO2-1 CO2-1 CO2 sensors
Name Photo Description
Vents SR 125/600 SR 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/900 SR 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/1200 SR 125/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KOM 125 KOM 125 Spring-loaded backdraft damper for round ducts
Vents KRV 125 KRV 125 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions