Unit of measurement | VUTR 200 VK EC L A21 | |
Connected air duct size | mm | 125 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50 |
Rated power | W | 171 |
Unit current | A | 1.31 |
Maximum airflow | m3/h | 270 |
Sound pressure level LpA at 3 m | dB(A) | 33 |
Heat recovery efficiency, max | % | 93 |
Heat exchanger type | - | Rotary |
Heat exchanger material | - | Aluminum |
Weight | kg | 52 |
Extract filter | - | G4 |
Supply filter | - | G4 (F7 optional) |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 60 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | VUTR 200 VK EC L A21 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
85.6 | A+ | 41.1 | A | 15.6 | E | |
Type of ventilation unit | Bidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | Regenerative | |||||
Thermal efficiency of heat recovery (%) | 88 | |||||
Maximum flow rate (m3/h) | 240 | |||||
Electric power input (W) | 170 | |||||
Reference flow rate (m3/s) | 0.047 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.411 | |||||
Control typology | Local demand control | |||||
Maximum internal leakage rates (%) | 3.3 | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Sound power level (dB(A)) | 45 | |||||
Declared typology | RVU BVU | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
217 | 869 | 217 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
9100 | 4652 | 2104 |
Name | Photo | Description |
---|---|---|
Vents A25 | The control panel with a sensor display | |
Vents A22 | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A22 WiFi | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Name | Photo | Description |
---|---|---|
Vents HR-S | Electro-mechanical humidistats | |
Vents CO2-1 | CO2 sensors |
Name | Photo | Description |
---|---|---|
Vents SR 125/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 125/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 125/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 125 | Spring-loaded backdraft damper for round ducts | |
Vents KRV 125 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo TF230 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |