Vents VUTR 700 TH EH EC A17

The heat recovery air handling units in sound- and heat-insulated casings are equipped with a rotary heat exchanger and a built-in heat pump
  • Power of electrical preheater: 2800 W
  • Maximum airflow: 830 m3/h
  • Sound pressure level LpA at 3 m: 52 dB(A)
  • Heat exchanger type: Rotary
  • Extract filter: G4
  • Supply filter: G4 (F7 опция), G4 (F7 option)
  • Sound insulation
  • Motor type: EC
  • Preheater: Built-in
  • Control: Remote Control
  • Casing material: Galvanized steel
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUTR 700 TH EH EC A17
Connected air duct size mm 160
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50
Rated power W 360
Power of electrical preheater W 2800
Unit current A 18.5
Maximum airflow m3/h 830
Sound pressure level LpA at 3 m dB(A) 52
Heat recovery efficiency, max % 85
Heat exchanger type - Rotary
Heat exchanger material - Aluminum
Weight kg 165
Extract filter - G4
Supply filter - G4 (F7 опция), G4 (F7 option)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 80
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Datasheet
"VENTS VUT R TN H/ EH ЕС" product description 05-2022
2.19 Mb
Manual
"VENTS VUT R TN H/ EH EC" user's manual 12-2023 (V107EN-02)
10.11 Mb
Image
VUTR 700 TH EH EC A17 - image 1
578 Kb
ØD B H L
249 748 750 1667
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents DPWC11200 DPWC11200 Humidity sensor
Name Photo Description
Vents DPWQ30600 DPWQ30600 VOC sensors
Vents DPWQ40200 DPWQ40200 CO2 sensor
Name Photo Description
Vents KOM 250 KOM 250 Spring-loaded backdraft damper for round ducts
Vents KRV 250 KRV 250 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo LF230 Belimo LF230 The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 700x352x48 G4 SF 700x352x48 G4 Panel filter G4
Vents SFK 700x351x27 G4 SFK 700x351x27 G4 G4 pocket filter