Series Vents UVU

Unidirectional ventilation units
  • Sound-insulated casing
  • BMS protocol: ModBus, Bacnet
  • Casing material: Aluzinc
The compact UVU unidirectional ventilation units with additional heating and cooling modules provide comfortable living conditions in any premises, such as logistics facilities or gyms.
Easy installation directly into the duct and the ability to combine sections allows achieving the required air parameters within an optimised time frame.
DESIGN
The panels of the casing are made of aluzinc (outer) and galvanized steel (inner), and are heat and sound insulated with 25 mm or 40 mm thick mineral wool depending on size. Maintenance is carried out from below through removable panels. Each unit size may comprise the following components to achieve the required air parameters:

  • V – fan
  • F – air filter class G4, F7
  • HW – water heater
  • CW – water cooler
  • CDX – freon cooler
  • HE – electric heater

APPLICATION
CONFIGURATIONS AND FUNCTIONAL UNITS

VF
Basic configuration

VFHW/CW
Configuration with filter and reversible water heat exchanger (heating/cooling)

VFHECW/CDX
Configuration with filter, electric heater and freon cooler

VFHE
Configuration with filter and electric heater

BASIC CONFIGURATION
V
Fan
  • Fan with EC motor, smooth adjustment
    0...10 V

F
Air filter
  • G4 panel filter
  • F7 panel filter

ADDITIONAL OPTIONS. HEATING
HW
Water heater
  • two-row, standard version
  • four-row, standard version

HE
Electric heater*
  • three-phase, rated power 9 kW
  • three-phase, rated power 18 kW
  • three-phase, rated power 36 kW
  • three-phase, rated power 48 kW
  • three-phase, rated power 72 kW

*The rated power can be increased by making the heater a separate section.

ADDITIONAL OPTIONS. COOLING
CW
Water cooler
  • two-row, standard version
  • four-row, standard version

CDX
R32/R410A freon cooler
  • two-row, standard version
  • four-row, standard version

CONFIGURATIONS AND PERFORMANCE

Filters: Connected air duct size: 440x280 mm
Lineup Vents UVU Casing performance Connected air duct size, mm Phases Maximum supply voltage, V Rated power supply fan, W Maximum airflow, m³/h Sound pressure level LpA at 3 m, dB(A) Reheater BMS protocol
40 mm
T3/TB4
440x280 1 240 532 1350 25 Optional ModBus
Bacnet
Datasheet
"VENTS UVU" product description 10-2024
922 Kb
Manual
"VENTS UVU" user’s manual 05-2025 (V244EN-01)
6.88 Mb
Manual
"AirVents automatic control system A29, A30, A31, A32" user’s manual 01-2026 (V201-EN-03)
5.62 Mb
Image
UVU - image 1
318 Kb