Ventilation unit VENTS VNV-1 80

  • Description
  • Modifications
  • Capacity diagram
  • Downloads
  • Certificates
  • Legend
  • Video
Description
Description
APPLICATION  
  • Exhaust ventilation of high-rise residential and non-residential premises.
  • Suitable for premises with mono-pipe ventilation system.
  • Mounting in kitchens, bathrooms, toilets, storerooms and other household rooms.
  • Installed into the plastic or fireproof casing.
  • For periodic or continuous operation.
DESIGN  
  • The front panel is made of high quality and durable ABS plastic.
  • Equipped with a polyether filter for motor and impeller protection against dust and dirt penetration (G4 filter class ).
  • The turnable front panel conceals possible inaccuracies of the fan casing installation.
  • Fastened to the casing by means of latches and requires no tools.
  • The impeller design provides increase of the fan efficiency and the motor service life.
MOTOR  
  • Energy efficient 2- or 3-speed motor with minimum energy demand.
  • Automatic maintaining of constant pressure and air flow in the duct.
  • Ball bearings increase the motor service life.
  • For precise characteristics, low noise level and safe operation each turbine is dynamically balanced while assembly.
MODIFICATIONS AND OPTIONS  
VNV-1 80 T — fan with timer.
VNV-1 80 TR — fan with regulated timer.
VNV-1 80 — 
fan with interval switch. 
VNV-1 80 F — 
fan with photosensor.
VNV-1 80 H — fan with humidity sensor.
VNV-2 80 — 
fan with front panel from ground alumunium.
VNV-2 80 Chrome — 
fan with front panel from mirror finish aluminium.
VNV-2 80 Gold —
 fan with front panel from golden mirror finish aluminium.
CONTROL  
  • Speed switching with the external manual switch. P3-1-300 switch for the three speed fan models and P2-1-300 for the two speed fan models. The speed switches are not included into the delivery set and are available upon order.

The grille fixation to the fan while mounting provides regulation of tne front panel

rotation angle with respect to the casing to conceal possible mounting inaccuracies.

FRONT PANEL MODIFICATIONS
MOUNTING EXAMPLE
  • The fan casing is mounted during construction works and connected to the main ventilation shaft.
  • Electric wiring for connection of the VNV-1 80 ventilation unit is led out through a special hole in the casing.
  • The front panel is covered with the protective cardboard plate supplied with the unit to avoid damages or contamination during finishing works in the room.
  • After finishing the works the protective cardboard plate is removed and the VNV-1 80 ventilation unit is installed into the casing and connected to the wiring.
 
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Downloads
Downloads
Name
User's manual "VENTS VN" (pdf 11.52Mb)
Download high quality image "VENTS VNV-1 80" (psd 2.38Mb)
Brochure "VENTS VNV-1 80" (pdf 522.95Kb)
Certificate LVD "VNV,VN" (pdf 2.02Mb)
Declaration of сonformity "VNV" (pdf 1.53Mb)
Declaration of сonformity "VN,VNV" (pdf 1.57Mb)
Certificate GS "VN" (pdf 412.38Kb)
Download image "VENTS VNV-1 80" for your website (png 571.22Kb)
Certificates
Certificates
<p>
	Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).</p>

Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).

<p>
	CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer).</p>

CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer).

<p>
	Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification). </p>

Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification).

<p>
	Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).</p>

Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).

<p>
	Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.</p>

Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.

<p>
	Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow). </p>

Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow).

<p>
	Insulation class: double insulation.</p>

Insulation class: double insulation.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Applicance protection class.</p>

Applicance protection class.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

RoHS (Restriction of Hazardous Substances Directive) is the directive on the restriction of the use of certain hazardous substances, was adopted in February 2003 by the European Union. RoHS (Restriction of Hazardous Substances Directive) is the directive on the restriction of the use of certain hazardous substances, was adopted in February 2003 by the European Union.
<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

Legend
Legend

Options for 2 speed fan models

  • T — timer modification
  • TR — adjustable timer modification
  • I — interval switch modification
  • F — built-in photosensor modification
  • Н humidity sensor modification
Video
Video

Share your opinion
I found this page useful to select the required products easy and quick
No difficulties with the site use. Everything is logical ad clear
The site produced a nice impression

Questionnaire
Basic parameter for domestic fan selection