Maßeinheit | Micra 200 ERV WiFi | |||||
Luftkanalgröße | mm | 100 | ||||
Versorgungsspannung min | V | 230 | ||||
Versorgungsspannung max | V | 230 | ||||
Frequenz der Netzversorgung | Hz | 50/60 | ||||
Leistung | W | 10 | 15 | 25 | 44 | 134 |
Stromaufnahme | A | 1 | ||||
Max. Förderleistung | m3/h | 30 | 60 | 90 | 120 | 200 |
Schalldruckpegel LpA @ 3 m | dB(A) | 12 | 22 | 30 | 36 | 45 |
Heat recovery efficiency | % | 85 | 81 | 75 | 68 | 66 |
Wärmetauschertyp | - | Counter flow | ||||
Wärmetauschermaterial | - | Enthalpy | ||||
Gewicht | kg | 55 | ||||
Abluftfilter | - | G4 | ||||
Zuluftfilter | - | G4 + F7 (H13 option) | ||||
Fördermitteltemperatur max | °С | 40 | ||||
Fördermitteltemperatur min | °С | -15 | ||||
Ambientlufttemperatur, min | °С | 1 | ||||
Ambientlufttemperatur, max | °С | 40 | ||||
Umgebungsluftfeuchtigkeit, max | % | 60 | ||||
Schutzart | - | IP22 | ||||
Motorschutzart | - | IP44 |
Warenzeichen | Vents | |||||
Modell | Micra 200 ERV WiFi | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Kalt | Durchschnittlich | Warm | |||
-69.7 | A+ | -35.2 | A | -12.8 | E | |
Typ des Lüftungsgeräts | Bidirectional | |||||
Antriebsart | Drehzahlregelung | |||||
Art des Wärmerückgewinnungssystems | Recuperative | |||||
Temperaturänderungsgrad der Wärmerückgewinnung (%) | 68 | |||||
Max. Luftvolumenstrom (m3/h) | 200 | |||||
Elektrische Eingangsleistung (W) | 134 | |||||
Bezugs-Luftvolumenstrom (m3/s) | 0.039 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.415 | |||||
Control typology | Local demand control | |||||
Maximum internal leakage rates (%) | 0.1 | |||||
Maximum external leakage rates (%) | 0.9 | |||||
Mischquote der Zwei-Richtung-Geräte (%) | 20 | |||||
Airflow sensitivity at +20 Pa and -20 Pa (%) | 0.93 | |||||
The indoor/outdoor air tightness (m3/h) | 7 | |||||
Angabe des Typs | RVU BVU | |||||
Sound power level (dB(A)) | 36 | |||||
The annual electricity consumption (AEC) (kWh/a) | Kalt | Durchschnittlich | Warm | |||
824 | 287 | 242 | ||||
The annual heating saved (AHS) (kWh/a) | Kalt | Durchschnittlich | Warm | |||
8161 | 4172 | 1886 |
Produktname | Foto | Beschreibung |
---|---|---|
Vents NB Micra 200 chrome | Lüftungshaube | |
Vents NB Micra 200 white | Lüftungshaube | |
Vents SF 201x162x20 G4 | Panel filter G4 | |
Vents SF 243x162x20 G4 | Panel filter G4 | |
Vents SF 502x162x40 F7 | Panelfilter F7 | |
Vents MK Micra 200 chrome | Montagesatz: Zwei Kunststoff-Lüftungsrohre; Außen-Lüftungshaube; Karton-Montageplatte | |
Vents MK Micra 200 white | Montagesatz: Zwei Kunststoff-Lüftungsrohre; Außen-Lüftungshaube; Karton-Montageplatte | |
Vents SF 502x162x40 H13 | Hepa-Filter H13 |
Produktname | Foto | Beschreibung |
---|---|---|
Vents CO2-1 | CO2 Sensor | |
Vents CO2-2 | CO2 Sensor |