Vents 120 Simple TH

Axial extract fans with thin front panels
  • Sound pressure level LpA at 3 m: 35 dB(A)
  • Casing material: Plastic
  • Timer: Turn off timer
Unit of measurement 120 Simple TH
Connected air duct size mm 120
Phases - 1
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 16
Unit current A 0.09
Maximum airflow m³/h 174
Sound pressure level LpA at 3 m dB(A) 35
Weight kg 0.74
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Impeller material - Plastic
Trademark Vents
Model 120 Simple TH
Specific energy consumption (SEC) (kWh/(m²/a)) Cold Average Warm
-53.5 A+ -26.4 B -10.9 E
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m³/h) 174
Electric power input (W) 16
Reference flow rate (m³/s) 0.034
Specific power input (SPI) (W/(m³/h)) 0.092
Control typology Local demand control
Maximum external leakage rates (%) 2.7
Declared typology RVU UVU
Sound power level (dB(A)) 55
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
75 75 75
The annual heating saved (AHS) (kWh/a) Cold Average Warm
5536 2830 1280
Datasheet
"VENTS Simple" product description 01-2024
3.35 Mb
Manual
"VENTS Simple" user's manual 05-2026 (V171EN-03)
1.78 Mb
Image
120 Simple TH - image 1
653 Kb
Ø D B L L1
120 175 94 15