Unit of measurement | CBF 200 | ||
Connected air duct size | mm | 100/150 | |
Phases | - | 1 | |
Minimum supply voltage | V | 220 | |
Maximum supply voltage | V | 240 | |
Power supply frequency | Hz | 50 | 60 |
Rated power | W | 20 | 29 |
Unit current | A | 0.1 | 0.13 |
Maximum airflow | m3/h | 130 | 210 |
Sound pressure level LpA at 3 m | dB(A) | 24 | 27 |
Weight | kg | 5.3 | |
Ambient air temperature min | °С | 1 | |
Ambient air temperature max | °С | 40 | |
Ingress protection rating | - | IPX2 |
Trademark | Vents | |||||
Model | CBF 200 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-26.9 | B | -10.5 | E | -1.1 | F | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | 2-speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 64 | |||||
Electric power input (W) | 25.5 | |||||
Reference flow rate (m3/s) | 0.024 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.212 | |||||
Control typology | Manual control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Sound power level (dB(A)) | 45 | |||||
Declared typology | RVU UVU | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
265 | 265 | 265 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
3355 | 1715 | 776 |
E | C | d | h | A | B | D | H | L1 | L2 |
---|---|---|---|---|---|---|---|---|---|
395 | 260 | 98 | 18 | 330 | 258 | 148 | 188 | 100 | 45 |
Name | Photo | Description |
---|---|---|
Vents P2-10 | Turning fan on/off and speed switching for multispeed fans |
Name | Photo | Description |
---|---|---|
Vents Polyvent 660 | Flexible PVC film non-insulated air ducts with steel wire frame (65 μm) |
Name | Photo | Description |
---|---|---|
Vents MVM 102 bVs N | Supply and exhaust metal hoods | |
Vents MVM 152 bVs N | Supply and exhaust metal hoods |
Name | Photo | Description |
---|---|---|
Vents MV 102 V ASA | Supply and exhaust hoods | |
Vents MV 152 V ASA | Supply and exhaust hoods |
Name | Photo | Description |
---|---|---|
Vents CB 60-110 | The clamps are designed for quick and reliable mounting and connection of various round ventilation system components. Clamps are the stainless steel quick-release clamps equipped with a stainless steel swing screw | |
Vents CB 60-165 | The clamps are designed for quick and reliable mounting and connection of various round ventilation system components. Clamps are the stainless steel quick-release clamps equipped with a stainless steel swing screw |