Vents DVUT 1200 HBE2 EC L A21 V.2

School floor-mounted AHUs
  • Power of electrical preheater: 3150 W
  • Power of electrical reheater: 2110 W
  • Sound pressure level LpA at 3 m: 30 dB(A)
  • Sound pressure level LpA at 1 m: 40 dB(A)
  • Heat exchanger type: Counter flow
  • Heat exchanger material: Polystyrene
  • Supply filter: ISO ePM1 60% (F7)
  • Extract filter: ISO Coarse >60% (G4)
  • Sound-insulated casing
  • Bypass: Auto
  • Preheater: Electric
  • Reheater: Electric
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Coated steel
  • CO2 sensor: Optional
  • PM2.5 sensor: Optional
  • Temperature sensor
Unit of measurement DVUT 1200 HBE2 EC L A21 V.2
Connected air duct size mm 400
Phases - 3
Minimum supply voltage V 400
Maximum supply voltage V 400
Power supply frequency Hz 50/60
Rated power W 345
Power of electrical preheater W 3150
Power of electrical reheater W 2110
Unit current A 18.7
Maximum airflow m³/h 1240
Sound pressure level LpA at 3 m dB(A) 30
Sound pressure level LpA at 1 m dB(A) 40
Heat recovery efficiency, max % 96
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 364
Supply filter - ISO ePM1 60% (F7)
Extract filter - ISO Coarse >60% (G4)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP20
Ambient air humidity max % 60
Ingress protection rating of the drive - IP44
Datasheet
"Single-room ventilation for schools and public spaces" catalog 2024
4.91 Mb
Manual
"VENTS DVUT 1200 HB EC V.2" user's manual 04-2024 (V142-1EN-03)
3.43 Mb
Manual
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
Manual
"NB DVUT HB" installation instruction 11-2020 (V113-14EN-01)
1.18 Mb
Manual
"VENTS DVUT/DVUE HB EC V.2" user's manual 04-2024 (V142EN-08)
3.49 Mb
Manual
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Image
DVUT 1200 HBE2 EC L A21 V.2 - image 1
212 Kb
Image
DVUT 1200 HBE2 EC L A21 V.2 - image 2
322 Kb
H H1 D H3 H4 H5 L L1 L2 L3
2106 2000 400 545 1110 70 1900 1951 265 535
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistat
Vents DPWC11200 DPWC11200 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Name Photo Description
Vents DPWQ30600 DPWQ30600 VOC sensors
Name Photo Description
Vents DPWQ40200 DPWQ40200 CO2 sensor
Name Photo Description
Vents SH-32 SH-32 Hydraulic U-trap to drain condensate from heat exchangers and coolers
Vents DN-2 DN-2 Drain pump for pumping out and draining condensation
Other accessories
Name Photo Description
Vents NB DVUT 1200 HB chrome NB DVUT 1200 HB chrome Outer ventilation hood
Vents NB DVUT 1200 HB white NB DVUT 1200 HB white Outer ventilation hood
Vents SF 540x450x48 F7 SF 540x450x48 F7 F7 panel filter
Vents SF 450x395x48 G4 SF 450x395x48 G4 Panel filter G4