Vents DVUT 500 HBE2 EC A21 V.2

School floor-mounted AHUs
  • Power of electrical preheater: 1050 W
  • Power of electrical reheater: 700 W
  • Sound pressure level LpA at 3 m: 38 dB(A)
  • Sound pressure level LpA at 1 m: 47 dB(A)
  • Heat exchanger type: Counter flow
  • Heat exchanger material: Polystyrene
  • Supply filter: ISO ePM1 60% (F7)
  • Extract filter: ISO Coarse >60% (G4)
  • Sound-insulated casing
  • Bypass: Auto
  • Preheater: Electric
  • Reheater: Electric
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Coated steel
  • CO2 sensor: Optional
  • PM2.5 sensor: Optional
  • Temperature sensor
Unit of measurement DVUT 500 HBE2 EC A21 V.2
Connected air duct size mm 250
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 370
Power of electrical preheater W 1050
Power of electrical reheater W 700
Unit current A 13.3
Maximum airflow m³/h 580
Sound pressure level LpA at 3 m dB(A) 38
Sound pressure level LpA at 1 m dB(A) 47
Heat recovery efficiency, max % 94
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 142
Supply filter - ISO ePM1 60% (F7)
Extract filter - ISO Coarse >60% (G4)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature max °С 40
Ambient air temperature min °С 1
Ingress protection rating - IP20
Ambient air humidity max % 60
Ingress protection rating of the drive - IP44
Minimum wall thickness mm 100
Maximum wall thickness mm 2000
Datasheet
"Single-room ventilation for schools and public spaces" catalog 2026
2.88 Mb
Manual
"VENTS DVUT 1200 HB EC V.2" user's manual 04-2024 (V142-1EN-03)
3.43 Mb
Manual
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
Manual
"NB DVUT HB" installation instruction 11-2020 (V113-14EN-01)
1.18 Mb
Manual
"VENTS DVUT/DVUE HB EC V.2" user's manual 04-2024 (V142EN-08)
3.49 Mb
Manual
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Image
DVUT 500 HBE2 EC A21 V.2 - image 1
212 Kb
Image
DVUT 500 HBE2 EC A21 V.2 - image 2
322 Kb
W W1 W2 L L1 H H1 H2 D
750 350 200 535 585 2170 1865 305 250
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistat
Vents DPWC11200 DPWC11200 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Name Photo Description
Vents DPWQ30600 DPWQ30600 VOC sensors
Name Photo Description
Vents DPWQ40200 DPWQ40200 CO2 sensor
Name Photo Description
Vents SH-32 SH-32 Hydraulic U-trap to drain condensate from heat exchangers and coolers
Vents DN-2 DN-2 Drain pump for pumping out and draining condensation
Other accessories
Name Photo Description
Vents NB DVUT 500 HB chrome NB DVUT 500 HB chrome Outer ventilation hood
Vents NB DVUT 500 HB white NB DVUT 500 HB white Outer ventilation hood
Vents SF 255x448x25 G4 (2 pcs.) SF 255x448x25 G4 (2 pcs.) Panel filter G4
Vents SF 449x318x60 F7 SF 449x318x60 F7 F7 panel filter