Vents DVUT 500 PB EC A21 V.2

School suspended AHUs
  • Sound pressure level LpA at 3 m: 34 dB(A)
  • Sound pressure level LpA at 1 m: 44 dB(A)
  • Heat exchanger type: Counter flow
  • Heat exchanger material: Polystyrene
  • Extract filter: ISO Coarse >60% (G4)
  • Supply filter: ISO ePM1 60% (F7)
  • Sound-insulated casing
  • Bypass: Auto
  • BMS protocol: ModBus
  • Control: Smartphone, Wireless control panel, Built-in control panel
  • Casing material: Galvanized steel
  • CO2 sensor: Optional
  • Temperature sensor: Built-in
Unit of measurement DVUT 500 PB EC A21 V.2
Connected air duct size mm 250
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 143
Unit current A 1.1
Maximum airflow m³/h 510
Rotation speed at 50hz - 1700
Sound pressure level LpA at 3 m dB(A) 34
Sound pressure level LpA at 1 m dB(A) 44
Heat recovery efficiency, max % 96
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 126
Extract filter - ISO Coarse >60% (G4)
Supply filter - ISO ePM1 60% (F7)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP20
Ingress protection rating of the drive - IP44
Datasheet
"Single-room ventilation for schools and public spaces" catalog 2024
4.91 Mb
Manual
"DVUT PB EC V.2" user's manual 11-2025 (V177EN-07)
7.64 Mb
Manual
"DVUT 1000 PB EC V.2" user's manual 04-2024 (V177-1EN-03)
6.27 Mb
Manual
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
Manual
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Image
DVUT 500 PB EC A21 V.2 - image 1
216 Kb
∅D A A1 A2 A3 B B1 B2 B3 H H1 N M
250 1500 1135 186 1422 850 181 530 207 458 221 504 41
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistat
Vents DPWC11200 DPWC11200 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Name Photo Description
Vents DPWQ30600 DPWQ30600 VOC sensors
Vents DPWQ40200 DPWQ40200 CO2 sensor
Name Photo Description
Vents SH-32 SH-32 Hydraulic U-trap to drain condensate from heat exchangers and coolers
Vents DN-2 DN-2 Drain pump for pumping out and draining condensation
Vents DN-2-DVUT P DN-2-DVUT P Boxed drain pump for pumping out and draining condensation
Other accessories
Name Photo Description
Vents SF 379x334x48 G4 SF 379x334x48 G4 Panel filter G4
Vents SF 379x254x48 F7 SF 379x254x48 F7 F7 panel filter