Unit of measurement | Enave-CT 200 P A21 | |
Connected air duct size | mm | 125 / 160 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 169 |
Unit current | A | 1.28 |
Maximum airflow | m3/h | 309 |
Sound pressure level LpA at 3 m | dB(A) | 34 |
Heat recovery efficiency, max | % | 78 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Enthalpy |
Weight | kg | 15 |
Extract filter | - | Coarse > 60 % |
Supply filter | - | Coarse > 60 % (option: ePM1 60 %) |
Transported air temperature (max) | °С | 45 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Ø D | Ø D1 | H | L | L1 | W | W1 | W2 | W3 |
---|---|---|---|---|---|---|---|---|
160 | 125 | 241 | 1160 | 685 | 680 | 642 | 610 | 541 |
Name | Photo | Description |
---|---|---|
Vents SF 200x165x48 Coarse 90% G4 |
![]() |
Panel filter G4 |
Vents SF 200x165x48 ePM1 65% F7 |
![]() |
F7 panel filter |
Name | Photo | Description |
---|---|---|
Vents A25 |
![]() |
The control panel with a sensor display |
Vents A22 |
![]() |
The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Vents A22 WiFi |
![]() |
The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Name | Photo | Description |
---|---|---|
Vents HV2 |
![]() |
Humidity sensor |
Vents CO2-3 |
![]() |
CO2 sensor |
Vents CO2-1 |
![]() |
CO2 sensors |
Vents CO2-2 |
![]() |
CO2 sensors |
Vents HR-S |
![]() |
Electro-mechanical humidistats |
Name | Photo | Description |
---|---|---|
Vents NKP 160-0,8-1 A21 V.2 |
![]() |
Heater for heat exchanger freeze protection |
Vents NKP 160-1,2-1 A21 V.2 |
![]() |
Heater for heat exchanger freeze protection |
Vents NKP 160-1,7-1 A21 V.2 |
![]() |
Heater for heat exchanger freeze protection |
Vents NKP 160-2,0-1 A21 V.2 |
![]() |
Heater for heat exchanger freeze protection |
Vents NKD 160-0,8-1 A21 V.2 |
![]() |
Duct heater for supply air post-heating with external control |
Vents NKD 160-1,2-1 A21 V.2 |
![]() |
Duct heater for supply air post-heating with external control |
Vents NKD 160-1,7-1 A21 V.2 |
![]() |
Duct heater for supply air post-heating with external control |
Vents NKD 160-2,0-1 A21 V.2 |
![]() |
Duct heater for supply air post-heating with external control |
Name | Photo | Description |
---|---|---|
Vents SR 160/600 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SR 160/900 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SR 160/1200 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KRV 160 |
![]() |
Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo TF230 |
![]() |
The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |