| Unit of measurement | MPA 700 E-9.0 EC A31 | |
| Minimum supply voltage | V | 400 |
| Maximum supply voltage | V | 400 |
| Power supply frequency | Hz | 50 |
| Rated power | W | 116 |
| Power of electrical reheater | W | 9000 |
| Unit current | A | 14.6 |
| Maximum airflow | m³/h | 760 |
| Sound pressure level LpA at 3 m | dB(A) | 41 |
| Weight | kg | 27 |
| Filter | - | Coarse 90% / G4 (option ePM1 70% / F7) |
| Transported air temperature (max) | °С | 40 |
| Transported air temperature (min) | °С | -30 |
| Ingress protection rating | - | IP22 |
| Ingress protection rating of the drive | - | IP44 |
| Trademark | Vents | |||||
| Model | MPA 700 E-9.0 EC A31 | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -53.9 | A+ | -26.8 | B | -11.3 | E | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 620 | |||||
| Electric power input (W) | 116 | |||||
| Reference flow rate (m³/s) | 0.139 | |||||
| Reference pressure difference (Pa) | 50 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.11 | |||||
| Control typology | Local demand control | |||||
| Maximum internal leakage rates (%) | 2.7 | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Sound power level (dB(A)) | 54 | |||||
| Declared typology | RVU UVU | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 58 | 58 | 58 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 5536 | 2830 | 1280 | ||||
| Name | Photo | Description |
|---|---|---|
| Vents SR 250/600 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 250/900 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 250/1200 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Name | Photo | Description |
|---|---|---|
| Vents KRV 250 |
|
Air dampers for automatic air flow control in round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents VVG 250 |
|
Flexible anti-vibration inserts for round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents Belimo TF24 |
|
The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
| Vents Belimo TF230 |
|
The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
| Name | Photo | Description |
|---|---|---|
| Vents SF 384x287x48 G4 |
|
Panel filter G4 |
| Vents SF 384x287x48 F7 |
|
F7 panel filter |