| Unit of measurement | Quiet 100 T | |
| Connected air duct size | mm | 100 |
| Phases | - | 1 |
| Minimum supply voltage | V | 220 |
| Maximum supply voltage | V | 240 |
| Power supply frequency | Hz | 50 |
| Rated power | W | 7.5 |
| Unit current | A | 0.049 |
| Maximum airflow | m³/h | 97 |
| Rotation speed at 50hz | - | 2165 |
| Sound pressure level LpA at 3 m | dB(A) | 25 |
| Weight | kg | 0.55 |
| Ambient air temperature min | °С | 1 |
| Ambient air temperature max | °С | 40 |
| Ingress protection rating | - | IP45 |
| Impeller material | - | Plastic |
| Trademark | Vents | |||||
| Model | Quiet 100 T | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -31.1 | B | -14.7 | E | -5.3 | F | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | Single speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 97 | |||||
| Electric power input (W) | 7.5 | |||||
| Reference flow rate (m³/s) | 0.019 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.077 | |||||
| Control typology | Manual control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU UVU | |||||
| Sound power level (dB(A)) | 45 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 97 | 97 | 97 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 3355 | 1715 | 776 | ||||
| ØD | B | H | L | L1 |
|---|---|---|---|---|
| 99 | 158 | 136 | 81 | 26 |