| Unit of measurement | Quietline 150 Extra | ||
| Speed | - | 1 | 2 |
| Connected air duct size | mm | 150 | |
| Phases | - | 1 | |
| Minimum supply voltage | V | 220 | |
| Maximum supply voltage | V | 240 | |
| Power supply frequency | Hz | 50 | |
| Rated power | W | 22 | 25 |
| Unit current | A | 0.103 | 0.109 |
| Maximum airflow | m³/h | 285 | 375 |
| Rotation speed at 50hz | - | 2300 | 2600 |
| Sound pressure level LpA at 3 m | dB(A) | 36 | 41 |
| Weight | kg | 1.3 | |
| Ambient air temperature min | °С | 1 | |
| Ambient air temperature max | °С | 40 | |
| Ingress protection rating | - | IPX4 | |
| Impeller material | - | Plastic | |
| Trademark | Vents | |||||
| Model | Quietline 150 Extra | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -31.1 | B | -14.7 | E | -5.3 | F | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | 2-speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 375 | |||||
| Electric power input (W) | 25 | |||||
| Reference flow rate (m³/s) | 0.079 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.077 | |||||
| Control typology | Manual control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU UVU | |||||
| Sound power level (dB(A)) | 56 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 97 | 97 | 97 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 3355 | 1715 | 776 | ||||