| Unit of measurement | Solo RA1-35-9 R V.2 | ||
| Minimum supply voltage | V | 220 | |
| Maximum supply voltage | V | 240 | |
| Power supply frequency | Hz | 50/60 | |
| Rated power | W | 2.40 | 3.70 |
| Unit current | A | 0.070 | 0.073 |
| Air flow in ventilation mode | m³/h | 30 | 46 |
| Air flow in heat recovery mode | m³/h | 15 | 23 |
| Sound pressure level LpA at 3 m | dB(A) | 21 | 26 |
| Sound pressure level LpA at 1 m | dB(A) | 31 | 36 |
| Heat recovery efficiency | % | 85 | |
| Heat recovery efficiency, max | % | 85 | |
| Filter | - | G3 | |
| Transported air temperature (max) | °С | 40 | |
| Transported air temperature (min) | °С | -15 | |
| Ambient air temperature min | °С | 1 | |
| Ambient air temperature max | °С | 40 | |
| Ambient air humidity max | % | 65 | |
| Ingress protection rating | - | IP24 | |
| Trademark | Vents | |||||
| Model | Solo RA1-35-9 R V.2 | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -83.3 | A+ | -42.1 | A+ | -18.5 | E | |
| Type of ventilation unit | Bidirectional | |||||
| Type of drive installed | 2-speed | |||||
| Type of heat recovery system | Regenerative | |||||
| Thermal efficiency of heat recovery (%) | 74 | |||||
| Maximum flow rate (m³/h) | 46 | |||||
| Electric power input (W) | 2.3 | |||||
| Reference flow rate (m³/s) | 0.008 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.08 | |||||
| Control typology | Local demand control | |||||
| Airflow sensitivity at +20 Pa and -20 Pa (%) | 0 | |||||
| Sound power level (dB(A)) | 41 | |||||
| Declared typology | RVU BVU | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 41 | 41 | 41 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 84 | 43 | 19 | ||||