Unit of measurement | Stream 150/160 EC | |
Connected air duct size | mm | 150/160 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 55 |
Unit current | A | 0.49 |
Maximum airflow | m3/h | 600 |
rotation speed at 50hz | - | 3506 |
Sound pressure level LpA at 3 m | dB(A) | 38 |
Weight | kg | 5 |
Transported air temperature (max) | °С | 55 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ingress protection rating | - | IPX4 |
Ingress protection rating of the drive | - | IP44 |
Ø D | B | L | H |
---|---|---|---|
150 (160) | 253 | 606 | 273 |
Name | Photo | Description |
---|---|---|
Vents SR 150/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 150/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 150/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 160/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 160/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 160/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents FB 150 | Panel filters | |
Vents FB 160 | Panel filters | |
Vents FBK 150-4 | Pocket filter | |
Vents FBK 150-5 | Pocket filter | |
Vents FBK 150-7 | Pocket filter | |
Vents FBK 160-4 | Pocket filter | |
Vents FBK 160-5 | Pocket filter | |
Vents FBK 160-7 | Pocket filter |
Name | Photo | Description |
---|---|---|
Vents NK 150-1,2-1 | Duct electric heater | |
Vents NK 150-1,7-1 | Duct electric heater | |
Vents NK 150-2,0-1 | Duct electric heater | |
Vents NK 150-2,4-1 | Duct electric heater | |
Vents NK 150-3,4-1 | Duct electric heater | |
Vents NK 160-1,2-1 | Duct electric heater | |
Vents NK 160-1,7-1 | Duct electric heater | |
Vents NK 160-2,0-1 | Duct electric heater | |
Vents NK 160-2,4-1 | Duct electric heater | |
Vents NK 160-3,4-1 | Duct electric heater |
Name | Photo | Description |
---|---|---|
Vents NKV 150-2 | Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units | |
Vents NKV 150-4 | Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units | |
Vents NKV 160-2 | Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units | |
Vents NKV 160-4 | Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units |
Name | Photo | Description |
---|---|---|
Vents KOM 150 | Spring-loaded backdraft damper for round ducts | |
Vents KOM 160 | Spring-loaded backdraft damper for round ducts | |
Vents KR 150 | Air damper for air flow control in round air ducts | |
Vents KR 160 | Air damper for air flow control in round air ducts |
Name | Photo | Description |
---|---|---|
Vents R-1/010 | Speed controller for EC motors |