| Unit of measurement | TT Silent-M 125 U | |||
| Speed | - | 1 | 2 | 3 |
| Connected air duct size | mm | 125 | ||
| Phases | - | 1 | ||
| Minimum supply voltage | V | 230 | ||
| Maximum supply voltage | V | 230 | ||
| Power supply frequency | Hz | 50/60 | ||
| Rated power | W | 9 | 12 | 23 |
| Unit current | A | 0.08 | 0.09 | 0.10 |
| Maximum airflow | m³/h | 155 | 214 | 340 |
| Rotation speed at 50hz | - | 1784 | 2473 | 2788 |
| Sound pressure level LpA at 3 m | dB(A) | 16 | 21 | 25 |
| Weight | kg | 4.6 | ||
| Transported air temperature (max) | °С | 60 | ||
| Ingress protection rating | - | IPX4 | ||
| Ingress protection rating of the drive | - | IPX4 | ||
| Impeller material | - | Plastic | ||
| Trademark | Vents | |||||
| Model | TT Silent-M 125 U | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -50 | A+ | -23 | D | -7.5 | F | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | Multi-speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 125 | |||||
| Electric power input (W) | 29 | |||||
| Reference flow rate (m³/s) | 0.024 | |||||
| Reference pressure difference (Pa) | 50 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.286 | |||||
| Control typology | Local demand control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Sound power level (dB(A)) | 28 | |||||
| Declared typology | RVU UVU | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 213 | 213 | 213 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 5536 | 2830 | 1280 | ||||
| Name | Photo | Description |
|---|---|---|
| Vents SRP 125/500 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/600 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/750 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/900 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/1200 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/1500 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/2000 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Name | Photo | Description |
|---|---|---|
| Vents FB K2 125 G4/F8 |
|
Panel filters of a high purification level |
| Vents FB K2 125 G4/C/F8 |
|
Panel filters of a high purification level |
| Vents FB K2 125 G4/H13 |
|
Panel filters of a high purification level |
| Vents FB K2 125 G4/C/H13 |
|
Panel filters of a high purification level |
| Vents FB 125 |
|
Round panel air filters |
| Vents FBV 125 |
|
Round panel air filters with a large filtration area |
| Vents FBK 125-4 |
|
Round bag air filters |
| Vents FBK 125-5 |
|
Round bag air filters |
| Vents FBK 125-7 |
|
Round bag air filters |
| Name | Photo | Description |
|---|---|---|
| Vents KOM 125 |
|
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
| Vents KOMu 125 |
|
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
| Vents KOM1 125 |
|
Backdraught gravity damper for shutting off air flow in round air ducts |
| Vents KR 125 |
|
Air dampers for controlling air flow in round air ducts |
| Vents KRV 125 |
|
Air dampers for automatic air flow control in round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents VVG 125 |
|
Flexible anti-vibration inserts for round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents NKV 125-2 |
|
Inline water supply air heaters or heater for air handling units with a round cross-section |
| Vents NKV 125-4 |
|
Inline water supply air heaters or heater for air handling units with a round cross-section |
| Name | Photo | Description |
|---|---|---|
| Vents NK 125-0,6-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-0,8-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-1,2-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-1,6-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-2,4-1 |
|
Round electric inline heaters with round cross-section |