Unit of measurement | VCU 2E 140x60 | |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50 |
Rated power | W | 148 |
Unit current | A | 0.64 |
Maximum airflow | m3/h | 515 |
Sound pressure level LpA at 3 m | dB(A) | 68 |
Weight | kg | 3.7 |
Transported air temperature (max) | °С | 45 |
Transported air temperature (min) | °С | -25 |
Ingress protection rating | - | IPX4 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | VCU 2E 140x60 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-52.4 | A+ | -25.3 | C | -9.8 | F | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 520 | |||||
Electric power input (W) | 148 | |||||
Reference flow rate (m3/s) | 0.101 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.224 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 68 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
118 | 118 | 118 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |
Name | Photo | Description |
---|---|---|
Vents RS-2 N |
![]() |
Speed controller |
Vents RS-1,5 V |
![]() |
Speed controller |
Vents RS-1,5 N |
![]() |
Speed controller |
Vents RS-1 V |
![]() |
Speed controller |
Vents RS-1 N |
![]() |
Speed controller |
Vents RS-1-400 |
![]() |
Speed controller |
Vents RS-1-300 |
![]() |
Speed controller |
Vents RS-2 V |
![]() |
Speed controller |
Vents RS-2,5 N |
![]() |
Speed controller |
Vents RS-2,5 V |
![]() |
Speed controller |
Vents RS-1,5-PS |
![]() |
Used in ventilation systems for switching on/off and speed control of single-phase fan motors with voltage control |
Vents RS-2,5-PS |
![]() |
Used in ventilation systems for switching on/off and speed control of single-phase fan motors with voltage control |
Vents RS-4,0-PS |
![]() |
Used in ventilation systems for switching on/off and speed control of single-phase fan motors with voltage control |
Vents RS-3,0-T |
![]() |
Applied in ventilation systems for speed switching ON/OFF and speed control of single-phase power-controlled motors |
Vents RS-5,0-T |
![]() |
Applied in ventilation systems for speed switching ON/OFF and speed control of single-phase power-controlled motors |
Vents RS-3,0-TA |
![]() |
Applied in ventilation systems for switching ON/OFF and speed controlling of single-phase power-controlled motors |
Vents RS-5,0-TA |
![]() |
Applied in ventilation systems for switching ON/OFF and speed controlling of single-phase power-controlled motors |
Vents RSA5E-2-P |
![]() |
Speed control enables not only selecting the comfortable ventilation mode for the periodically visited premises but reducing the energy consumption for the ventilation |
Vents RSA5E-2-M |
![]() |
Speed controls enables not only selecting the comfortable ventilation mode for the periodically visited premises but reducing the energy consumption for the ventilation |
Vents RSA5E-3-M |
![]() |
Speed controls enables not only selecting the comfortable ventilation mode for the periodically visited premises but reducing the energy consumption for the ventilation |
Vents RSA5E-4-M |
![]() |
Speed controls enables not only selecting the comfortable ventilation mode for the periodically visited premises but reducing the energy consumption for the ventilation |
Vents RSA5E-3,5-T |
![]() |
Speed controllers are applied for air flow control of single phase fans by means of motor step speed control |
Vents RSA5E-5,0-T |
![]() |
Speed controllers are applied for air flow control of single phase fans by means of motor step speed control |
Name | Photo | Description |
---|---|---|
Vents RT-10 |
![]() |
Temperature regulator |
Name | Photo | Description |
---|---|---|
Vents T-1,5 N |
![]() |
Sensor |
Vents TH-1,5 N |
![]() |
Sensor |
Vents TF-1,5 N |
![]() |
Sensor |
Vents TP-1,5 N |
![]() |
Sensor |