Vents VUE 180 P5B EC A14

Heat recovery air handling units in sound- and heat-insulated casings equipped with an enthalpy counter-flow heat exchanger
  • Maximum airflow: 220 m3/h
  • Sound pressure level LpA at 3 m: 33 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: G4
  • Supply filter: G4, F7
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Bypass: Manual
  • Control: Remote Control
  • Casing material: EPP
  • Installation in any position
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUE 180 P5B EC A14
Connected air duct size mm 150
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 87
Unit current A 0.71
Maximum airflow m3/h 220
Sound pressure level LpA at 3 m dB(A) 33
Heat recovery efficiency, max % 94
Heat exchanger type - Counter flow
Heat exchanger material - Enthalpy
Weight kg 14
Extract filter - G4
Supply filter - G4, F7
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents VUE 180 P5B EC A14 49 180 2018
Trademark Vents
Model VUE 180 P5B EC A14
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
80.7 A+ 42.2 A+ 17.5 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 85
Maximum flow rate (m3/h) 180
Electric power input (W) 77
Reference flow rate (m3/s) 0.035
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.248
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 49
Declared typology RVU BVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
713 176 131
The annual heating saved (AHS) (kWh/a) Cold Average Warm
8979 4590 2075
Datasheet
"VENTS VUT/VUE 180 P5B EC" product description 01-2023
2.64 Mb
Manual
"VENTS VUT/VUE 180 P5(B) EC" user's manual 03-2024 (V170EN-08)
2.46 Mb
Manual
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
Manual
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Manual
"Sensor control panel A14/A15" user’s manual 04-2019 (V55-7EN-02)
1.21 Mb
BIM/CAD models
VUT/VUE P(5)B EC
1.65 Mb
Image
VUE 180 P5B EC A14 - image 1
370 Kb
Vents VUE 180 P5B EC A14 - Dimensions
ØD B B2 H L L1
150 600 326 264 900 1009
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents KRV 150 KRV 150 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo LF230 Belimo LF230 The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 214x186x18 G4 SF 214x186x18 G4 Panel filter G4
Vents SF 214x186x48 F7 SF 214x186x48 F7 F7 panel filter