Vents VUE 250 H mini A1

Air handling units equipped with an enthalpy cross flow heat exchanger
  • Maximum airflow: 260 m3/h
  • Sound pressure level LpA at 3 m: 47 dB(A)
  • Heat exchanger type: Cross flow
  • Extract filter: G4
  • Supply filter: G4 (F8 PM2.5 81 %- option)
  • Sound insulation
  • Motor type: AC
  • Enthalpy heat exchanger
  • Control: Remote Control
  • Casing material: Galvanized steel
Unit of measurement VUE 250 H mini A1
Connected air duct size mm 125
Speed - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 126
Unit current A 0.6
Maximum airflow m3/h 260
Sound pressure level LpA at 3 m dB(A) 47
Heat recovery efficiency, max % 78
Heat exchanger type - Cross flow
Heat exchanger material - Polystyrene
Weight kg 26
Extract filter - G4
Supply filter - G4 (F8 PM2.5 81 %- option)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 80
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Datasheet
"VENTS VUT/VUE 250 V/H mini" product description 04-2024
723 Kb
Manual
"VENTS VUT(VUE) 250 V(H) mini A12 / A1" user's manual 12-2023 (V25EN-06)
8.62 Mb
Image
VUE 250 H mini A1 - image 1
408 Kb
Vents VUE 250 H mini A1 - Dimensions
ØD B H H1 L L1
125 300 443 43 713 810
Other accessories
Name Photo Description
Vents SF 240x184x40 G4 SF 240x184x40 G4 Panel filter G4
Vents SF 240x184x40 F8 SF 240x184x40 F8 F8 panel filter
Name Photo Description
Vents SR 125/600 SR 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/900 SR 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/1200 SR 125/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/600 SRF 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/900 SRF 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/2000 SRF 125/2000 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KOM 125 KOM 125 Spring-loaded backdraft damper for round ducts
Vents KR 125 KR 125 Air damper for air flow control in round air ducts