Vents VUT 1000 H

Air handling units in the compact sound- and heat-insulated casing
  • Maximum airflow: 1200 m3/h
  • Sound pressure level LpA at 3 m: 60 dB(A)
  • Heat exchanger type: Cross flow
  • Extract filter: G4
  • Supply filter: G4
  • Sound insulation
  • Motor type: AC
  • Control: Remote Control
  • Casing material: Galvanized steel
Unit of measurement VUT 1000 H
Connected air duct size mm 249
Speed - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 820
Unit current A 3.6
Maximum airflow m3/h 1200
Sound pressure level LpA at 3 m dB(A) 60
Heat recovery efficiency, max % 88
Heat exchanger type - Cross flow
Heat exchanger material - Polystyrene
Weight kg 88
Extract filter - G4
Supply filter - G4
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
ambient air temperature min °С 10
ambient air temperature max °С 50
ambient air humidity max % 80
Ingress protection rating - IP22
Datasheet
"VENTS VUT H" product description 01-2023
1.33 Mb
Certificates
Certificate LVD "VUT H"
230 Kb
Certificates
Certificate GS "VUT H"
229 Kb
Certificates
Declaration of сonformity "VUT H"
1.65 Mb
Image
VUT 1000 H - image 1
511 Kb
Manual
"VENTS VUT H" user's manual 10-2019 (V26EN-04)
2.38 Mb
Vents VUT 1000 H - Dimensions
ØD B B1 B2 B3 H H1 H2 L L1
248 548 496 60 213 794 290 200 802 850
Name Photo Description
Vents SR 250/600 SR 250/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 250/900 SR 250/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 250/1200 SR 250/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 250/600 SRF 250/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 250/900 SRF 250/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 250/2000 SRF 250/2000 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KOM 250 KOM 250 Spring-loaded backdraft damper for round ducts
Vents KR 250 KR 250 Air damper for air flow control in round air ducts
Other accessories
Name Photo Description
Vents SF 450x295x48 G4 SF 450x295x48 G4 Panel filter G4
Vents VL C4 300/450 VL C4 300/450 Summer block