Unit of measurement | VUT 600 EH | |
Connected air duct size | mm | 249 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 390 |
Power of electrical reheater | W | 4000 |
Unit current | A | 19.1 |
Maximum airflow | m3/h | 600 |
Sound pressure level LpA at 3 m | dB(A) | 48 |
Heat recovery efficiency, max | % | 85 |
Heat exchanger type | - | Cross flow |
Heat exchanger material | - | Polystyrene |
Weight | kg | 54 |
Extract filter | - | G4 |
Supply filter | - | G4 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 80 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | VUT 600 EH | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-46.5 | A+ | -15.9 | E | 4.2 | G | |
Type of ventilation unit | Bidirectional | |||||
Type of drive installed | Multi-speed | |||||
Type of heat recovery system | Recuperative | |||||
Thermal efficiency of heat recovery (%) | 64 | |||||
Maximum flow rate (m3/h) | 550 | |||||
Electric power input (W) | 395 | |||||
Reference flow rate (m3/s) | 0.107 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.675 | |||||
Control typology | Manual control | |||||
Maximum internal leakage rates (%) | 2.7 | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU BVU | |||||
Sound power level (dB(A)) | 65 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
1428 | 891 | 846 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
7343 | 3754 | 1697 |
ØD | B | B1 | B2 | B3 | H | H2 | H3 | L | L1 | L2 |
---|---|---|---|---|---|---|---|---|---|---|
199 | 497 | 403 | 248 | 348 | 554 | 111 | 230 | 954 | 996 | 1054 |
Name | Photo | Description |
---|---|---|
Vents SR 200/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 200/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 200/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 200/2000 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 200 | Spring-loaded backdraft damper for round ducts | |
Vents KR 200 | Air damper for air flow control in round air ducts |
Name | Photo | Description |
---|---|---|
Vents SF 438x215x48 G4 | Panel filter G4 | |
Vents VL C4 300/300 | Summer block |