Unit of measurement | VUT 800 EH | |
Connected air duct size | mm | 249 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 490 |
Power of electrical reheater | W | 9000 |
Unit current | A | 15.16 |
Maximum airflow | m3/h | 800 |
Sound pressure level LpA at 3 m | dB(A) | 48 |
Heat recovery efficiency, max | % | 78 |
Heat exchanger type | - | Cross flow |
Heat exchanger material | - | Polystyrene |
Weight | kg | 85 |
Extract filter | - | G4 |
Supply filter | - | G4 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 80 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | VUT 800 EH | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-50.4 | A+ | -19.8 | E | 0.3 | G | |
Type of ventilation unit | Bidirectional | |||||
Type of drive installed | Multi-speed | |||||
Type of heat recovery system | Recuperative | |||||
Thermal efficiency of heat recovery (%) | 64 | |||||
Maximum flow rate (m3/h) | 700 | |||||
Electric power input (W) | 490 | |||||
Reference flow rate (m3/s) | 0.136 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.551 | |||||
Control typology | Manual control | |||||
Maximum internal leakage rates (%) | 2.7 | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU BVU | |||||
Sound power level (dB(A)) | 68 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
1272 | 735 | 690 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
7343 | 3754 | 1697 |
ØD | B | B1 | B2 | B3 | H | H1 | H2 | H3 | L | L1 | L2 |
---|---|---|---|---|---|---|---|---|---|---|---|
249 | 613 | 460 | 306 | 386 | 698 | 832 | 154 | 280 | 1071 | 1117 | 1171 |
Name | Photo | Description |
---|---|---|
Vents SR 250/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 250/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 250/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 250/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 250/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 250/2000 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 250 | Spring-loaded backdraft damper for round ducts | |
Vents KR 250 | Air damper for air flow control in round air ducts |
Name | Photo | Description |
---|---|---|
Vents SF 550x253x48 G4 | Panel filter G4 | |
Vents VL C4 300/300 | Summer block |