VENTS VUT 800 EH

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Technical data
  • Designation key
  • Accessories
Description
Description
DESCRIPTION
  • Air handling units VUT EH with electric heater are the complete air handling units designed to provide both supply and exhaust ventilation with air filtering and heat recovery.

  • The exhaust air energy is used to heat up the supply fresh air through the heat exchanger.
  • All the models are designed for connection with Ø 125, 150, 160, 200, 250, 315 mm round ducts.
MODIFICATIONS FILTER
  • VUT EH – a range of compact energy saving air handling units (AHU) equipped with supply and exhaust centrifugal fans, cross-flow heat exchanger, electric heater and air filters.

  • Two incorporated G4 panel filters for extract air ventilation are supplied with the unit.

HEATER CASING
  • The electric heater at outlet from the heat exchanger is designed for warming up of supply air up to the set level if heat recovery is not enough to attain the set supply air temperature.

  • The casing is made of aluminum-zinc compound with 25 mm thick mineral wool heat- and sound-insulating layer.

FANS  
  • The units are equipped with supply and exhaust centrifugal double-inlet fans with forward curved blades and built-in thermostat with automatic restart.

  • The electric motors and impellers are dynamically balanced in two planes.
  • The ball-bearings used with motors are designed for at least 40 000 hours operation and are maintenance-free.
HEAT EXHANGER  
  • The heat exchangers have high efficiency and are made of polystyrol. 

  • The unit is also equipped with the drain pan for condensate drainage.
AUTOMATION AND CONTROL SYSTEM VUT EH CONTROL AND PROTECTION FUNCTIONS
  • The unit incorporates an integrated automation and control system with a multi-functional control panel with LCD display.
  • The standard delivery set includes 10 m connection cable for connection to the remote control panel.
  • The unit has the freezing protection function to prevent the heat exchanger freezing by means of actuating the bypass damper and controlling water heater.
  • As the temperature sensor warns of the freezing danger, the bypass air damper is opened and the intake air is directed through the air duct beside the heat exchanger.
  • As the heat exchanger is warmed the supply air temperature rises up to the set level while passing through the heater.
  • Meanwhile the warm extract air warms up the heat exchanger.
  • After the freezing danger is no longer imminent, the bypass damper shuts the bypass duct and the unit reverts to the standard operation mode.
  • Control from the control panel: switching on/off, speed selection, timer, faults;
  • Maintaining the set room temperature by the sensor on the control panel – smooth heating capacity control;
  • Three-speed fan speed control (low-medium-high);
  • Unit operation according to daily and week schedule (timer adjustable from the control panel);
  • Safe start-up/shutdown of the fans;
  • Electric heater overheating protection by the temperature sensor installed in the supply air duct and by two overheating thermostats, one thermostat activated at 60 °C with automatic reset and another thermostat activated at 90 °C with manual reset. Blowing of the heating elements for heat removing at the end of the heating cycle;
  • Filter clogging control by filter time.
MOUNTING OPTIONS
  • The unit is designed for indoor mounting. While mounting the unit provide the correct condensate collection and drainage. 
  • Access for the unit servicing and filter cleaning is from the side panels on the left from supply air side.
  • For attenuation of sound generated by the fans it is recommended to install the duct silencer (refer SR) from inside before the unit.
  • For vibration absorbing it is recommended to install the flexible antivibration connectors (refer VVG) on both sides of the unit.
Characteristics
Characteristics
Parameter VUT 800 EH
Measurement unit
Frequency 50/60 Hz
Phase 3 ˜
Voltage 400 V
Maximum fan power 2 pcs. x 245 W
Electric heater power 9000 W
Air capacity 800 m³/h
Electric heater current Electric heater current 13 A
Total unit power 9490 W
Total unit current 15.16 A
Fan current 2 pcs. x 1.08 A
RPM 1650 min-1
Maximum transported air temperature -25..+40 °С
Heat recovery efficiency 85 -
Sound pressure level at 3 m distance 48 dBА
Heating electric heating -
Casing material aluzinc -
Insulation 50 mm mineral wool -
Filter: extract G4 -
Filter: supply * option G4 -
Connected air duct diameter 250 mm
Mass 85 kg
Heat exchanger type cross-flow -
Heat exchanger material polystyrol -
SEC Class E -
Type supply and exhaust with heat recovery -
Mounting floor mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Name
Certificate LVD "VUT EH" (pdf 233.04Kb)
Certificate CB Test Report "VUT EH" (pdf 19.7Mb)
Certificate GS "VUT EH" (pdf 188.26Kb)
Download high quality image "VENTS VUT EH (ErP 2016)" (psd 4.6Mb)
Brochure "VENTS VUT EH/ WH" (pdf 5.67Mb)
Declaration of сonformity "VENTS VUT EH" (pdf 1.58Mb)
User's manual "VENTS VUT EH" (pdf 3.61Mb)
Download image "VENTS VUT EH (ErP 2016)" for your website (png 513.64Kb)
User's manual “Control Panel SYNERGY А16” (pdf 2.29Mb)
Dimensions
Characteristics
VENTS VUT 800 EH
Parameter Value Measurement unit
∅D 249 mm
B 613 mm
B1 460 mm
B2 306 mm
B3 386 mm
H 698 mm
H1 832 mm
H2 154 mm
H3 280 mm
L 1071 mm
L1 1117 mm
L2 1171 mm
Technical data
Technical data
Sound-power level Octave-frequency band [Hz]
  Hz Gen 63 125 250 500 1000 2000 4000 8000
LwA to inlet dBA 60 57 55 56 60 53 48 46 43
LwA to outlet dBA 58 59 62 61 54 54 51 50 46
LwA to environment dBA 38 45 46 38 40 32 26 28 24

 

Designation key
Designation key
Series Rated air flow [m3/h] Heater type Duct connection
VENTS VUT 350; 500; 530; 600; 800; 1000; 1500; 2000
E: electric
H: horizontal
Accessories
Accessories
Model G4 panel filter Silencers Back valves Air dampers Clamps Summer blocks
VUT 350 EH SF 438x215x48 G4 SR 125 600/900/1200 SRF 125 600/900/1200 KOM 125 KR 125 С 125 VL C4 300/300
VUT 500 EH SR 150 600/900/1200 SRF 150 600/900/1200 KOM 150 KR 150 C 150
VUT 530 EH SR 160 600/900/1200 SRF 160 600/900/1200 KOM 160 KR 160 C 160
VUT 600 EH SR 200 600/900/1200 SRF 200 600/900/1200 KOM 200 KR 200 C 200
VUT 800 EH SF 550x253x48 G4 SR 250 600/900/1200 SRF 250 600/900/1200 KOM 250 KR 250 C 250 VL C4 300/300*2 
VUT 1000 EH
VUT 1500 EH SF 780x273x48 G4  SR 315 600/900/1200 SRF 315 600/900/1200 KOM 315 KR 315 C 315 VL C4 300/384
VUT 2000 EH