Vents VUTR 601 VE EC R A21

Vents VUTR 601 VE EC R A21 - Vertical air handling units with a sorption rotary heat exchanger
New
Vertical air handling units with a sorption rotary heat exchanger
  • Power of electrical reheater: 1400 W
  • Sound pressure level LpA at 3 m: 29 dB(A)
  • Heat exchanger type: Condensation rotary
  • Extract filter: G4 / Coarse > 60%
  • Supply filter: G4 / Coarse > 60% (option F7 / ePM1 60%)
  • In sound-insulated casing
  • Motor type: EC
  • Reheater: Built-in
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Coated steel
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUTR 601 VE EC R A21
Connected air duct size mm 200
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 336
Power of electrical reheater W 1400
Unit current A 8.51
Maximum airflow m3/h 747
Sound pressure level LpA at 3 m dB(A) 29
Heat recovery efficiency, max % 87
Heat exchanger type - Condensation rotary
Weight kg 90
Extract filter - G4 / Coarse > 60%
Supply filter - G4 / Coarse > 60% (option F7 / ePM1 60%)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents VUTR 601 VE EC R A21 50 675 2016
Trademark Vents
Model VUTR 601 VE EC R A21
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-86.2 A+ -42.5 A+ -17.5 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Regenerative
Thermal efficiency of heat recovery (%) 84
Maximum flow rate (m3/h) 675
Electric power input (W) 304
Reference flow rate (m3/s) 0.128
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.24
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 50
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
127 127 127
The annual heating saved (AHS) (kWh/a) Cold Average Warm
8938 4569 2066
Datasheet
"VENTS VUTR V EC" product description 03-2025
1.5 Mb
Manual
"VENTS VUTR V EC" user’s manual 02-2025 (V287EN-02)
8.01 Mb
BIM/CAD models
VUTR 281 / 401 V EC - BIM model
1.59 Mb
BIM/CAD models
VUTR 601 V EC - BIM model
1.47 Mb
BIM/CAD models
VUTR 601 VE EC R А21 - CAD model
1.26 Mb
Image
VUTR 601 VE EC R A21 - image 1
481 Kb
H W L H1 W1 W2 W3 L1 L2 D D1
750 900 609 828 427 192 140 248 167 200 125
Name Photo Description
Vents A25 A25 Touch screen control panel for controlling industrial and residential air handling units
Vents A22 A22 Control panels for controlling industrial and residential air handling units
Vents A22 WiFi A22 WiFi Control panels for controlling industrial and residential air handling units
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistat
Name Photo Description
Vents SR 200/600 SR 200/600 Silencers made of galvanized steel filled with non-combustible sound-absorbing material
Vents SR 200/900 SR 200/900 Silencers made of galvanized steel filled with non-combustible sound-absorbing material
Vents SR 200/1200 SR 200/1200 Silencers made of galvanized steel filled with non-combustible sound-absorbing material
Name Photo Description
Vents KRV 200 KRV 200 Air dampers for automatic air flow control in round ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 522x240x48 Coarse 90% G4 SF 522x240x48 Coarse 90% G4 Panel filter G4
Vents SF 522x240x40 ePM1 60% F7 SF 522x240x40 ePM1 60% F7 F7 panel filter