T2 / TB2 / L1 / D1
The construction of the case with a PVC profile ensures the absence of thermal bridges, minimizes heat loss and reduces the noise level.
Size | Nominal air flow, m3/h | Instalation type | Overall hight,
mm | Heat exchanger material | Unit location | Service side | Energy-saving features |
AVS10
CFP800 | 800 | suspended | 400 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS10 CFP1200 | 1200 | suspended | 400 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS10 CFP1800 | 1800 | suspended | 450 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS20 CFP2400 | 2400 | suspended | 500 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS30 CFP3300 | 3300 | suspended | 500 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS40 CFP4200 | 4200 | suspended | 590 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS55 CFP5400 | 5400 | suspended | 950 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS65 CFP6600 | 6600 | suspended | 950 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS95 CFP8700 | 8700 | suspended | 1200 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
Size | Nominal air flow, m3/h | Instalation type | Overall hight,
mm | Heat exchanger material | Unit location | Service side | Energy-saving features |
AVS10 RV1200 | 1200 | floor mounted, vertical | 760 | condensation / enthalpy / sorption | indoor | Left/
Right | T2/TB2 |
AVS10 RV1800 | 1800 | floor mounted, vertical | 880 | condensation / enthalpy / sorption | indoor | Left/
Right | T2/TB2 |
AVS20 RV2400 | 2400 | floor mounted, vertical | 880 | condensation / enthalpy / sorption | indoor | Left/
Right | T2/TB2 |
AVS30 RV3300 | 3300 | floor mounted, vertical | 1200 | condensation / enthalpy / sorption | indoor | Left/
Right | T2/TB2 |
AVS40 RV4200 | 4200 | floor mounted, vertical | 1300 | condensation / enthalpy / sorption | indoor | Left/
Right | T2/TB2 |
AVS55 RV5400 | 5400 | floor mounted, vertical | 1350 | condensation / enthalpy / sorption | indoor | Left/
Right | T2/TB2 |
AVS65 RV6600 | 6600 | floor mounted, vertical | 1350 | condensation / enthalpy / sorption | indoor | Left/
Right | T2/TB2 |
AVS95 RV8700 | 8700 | floor mounted, vertical | 1730 | condensation / enthalpy / sorption | indoor | Left/
Right | T2/TB2 |
Size | Nominal air flow, m3/h | Instalation type | Overall depth, mm | Heat exchanger material | Unit location | Service side | Energy-saving features |
AVS10 CFV1200 Slim | 1200 | floor mounted, vertical | 680 | polystyrene/ aluminum | indoor | Left/
Right | T2/TB2 |
AVS10 CFV1800 Slim | 1800 | floor mounted, vertical | 680 | polystyrene/ aluminum | indoor | Left/
Right | T2/TB2 |
AVS20 CFV2400 Slim | 2400 | floor mounted, vertical | 680 | polystyrene/ aluminum | indoor | Left/
Right | T2/TB2 |
AVS10 CFV1200 | 1200 | floor mounted, vertical | 760 | polystyrene/ aluminum | indoor | Left/
Right | T2/TB2 |
AVS10 CFV1800 | 1800 | floor mounted, vertical | 880 | polystyrene/ aluminum | indoor | Left/
Right | T2/TB2 |
AVS20 CFV2400 | 2400 | floor mounted, vertical | 880 | polystyrene/ aluminum | indoor | Left/
Right | T2/TB2 |
AVS30 CFV3300 | 3300 | floor mounted, vertical | 1200 | polystyrene/ aluminum | indoor | Left/
Right | T2/TB2 |
AVS40 CFV4200 | 4200 | floor mounted, vertical | 1300 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS55 CFV5400 | 5400 | floor mounted, vertical | 1350 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS65 CFV6600 | 6600 | floor mounted, vertical | 1350 | polystyrene/
aluminum | indoor | Left/
Right | T2/TB2 |
AVS95 CFV8700 | 8700 | floor mounted, vertical | 1730 | polystyrene/ aluminum | indoor | Left/
Right | T2/TB2 |