Vents Breezy Eco 160

Vents Breezy Eco 160 - Single-room heat recovery ventilator
New
Single-room heat recovery ventilator
  • Air flow in heat recovery mode: 48 m3/h
  • Sound pressure level LpA at 3 m: 40 dB(A)
  • Sound pressure level LpA at 1 m: 50 dB(A)
  • Filter: G3
  • Motor type: EC
  • Control: Smartphone
  • Casing material: ABS Plastic
  • Temperature sensor
Unit of measurement Breezy Eco 160
Phases - 1
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50/60
Rated power W 3 5 8
Unit current A 0.02 0.03 0.04
Maximum airflow m3/h
Air flow in ventilation mode m3/h 10 30 48
Air flow in heat recovery mode m3/h 10 30 48
Sound pressure level LpA at 3 m dB(A) 14 27 40
Sound pressure level LpA at 1 m dB(A) 24 36 50
Heat recovery efficiency, max % 92
Heat exchanger material - Ceramic
Filter - G3
Transported air temperature (max) °С 50
Transported air temperature (min) °С -30
Ambient air humidity max % 70
Ingress protection rating - IPX4
Vents Breezy Eco 160 46 48 2016
Trademark Vents
Model Breezy Eco 160
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-81.2 A+ -40 A -16.4 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Regenerative
Thermal efficiency of heat recovery (%) 74
Maximum flow rate (m3/h) 48
Electric power input (W) 8
Reference flow rate (m3/s) 0.01
Specific power input (SPI) (W/(m3/h)) 0.2
Control typology Local demand control
Maximum internal leakage rates (%) 0.1
Maximum external leakage rates (%) 0.9
Mixing rate (%) 20
Airflow sensitivity at +20 Pa and -20 Pa (%) 0.93
The indoor/outdoor air tightness (m3/h) 7
Sound power level (dB(A)) 46
Declared typology RVU BVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
116 116 116
The annual heating saved (AHS) (kWh/a) Cold Average Warm
84 43 19
Datasheet
"Breezy Eco" product description 05-2024
1.47 Mb
Manual
"Breezy Eco" user's manual 10-2024 (V271EN-02)
4.26 Mb
Image
Breezy Eco 160 - image 1
450 Kb
ØD L L1
162 540 439