Vents Enave-C 200 P A14

Vents Enave-C 200 P A14 - Heat recovery air handling units in sound- and heat-insulated casings made of expanded polypropylene
Coming soon
Heat recovery air handling units in sound- and heat-insulated casings made of expanded polypropylene
  • Maximum airflow: 309 m3/h
  • Sound pressure level LpA at 3 m: 34 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: Coarse > 60 %
  • Supply filter: Coarse > 60 % (опція: ePM1 60 %)
  • Sound insulation
  • Motor type: EC
  • Bypass: Manual
  • Control: Wired control panel
  • Casing material: EPP
  • Humidity sensor: Optional
  • CO2 sensor: Optional
Unit of measurement Enave-C 200 P A14
Connected air duct size mm 125 / 160
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 169
Unit current A 1.28
Maximum airflow m3/h 309
Sound pressure level LpA at 3 m dB(A) 34
Heat recovery efficiency, max % 87
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 12
Extract filter - Coarse > 60 %
Supply filter - Coarse > 60 % (опція: ePM1 60 %)
Transported air temperature (max) °С 45
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Datasheet
"VENTS Enave-C P" product description 01-2024
1.44 Mb
Manual
"VENTS Enave-C P" user's manual 08-2024 (V281EN-01)
7.57 Mb
Image
Enave-C 200 P A14 - image 1
281 Kb
Vents Enave-C 200 P A14 - Dimensions
Ø D Ø D1 H L L1 W W1 W2 W3
160 125 241 1160 685 680 642 610 541
Other accessories
Name Photo Description
Vents SF 200x165x48 Coarse 90% G4 SF 200x165x48 Coarse 90% G4 Panel filter G4
Vents SF 200x165x48 ePM1 65% F7 SF 200x165x48 ePM1 65% F7 F7 panel filter
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents SR 160/600 SR 160/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/900 SR 160/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/1200 SR 160/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KRV 160 KRV 160 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions