Vents Enave-T 240 P A14

Heat recovery air handling unit in sound- and heat-insulated casing made of expanded polypropylene
  • Maximum airflow: 313 m3/h
  • Sound pressure level LpA at 3 m: 35 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: Coarse > 60 % (G4)
  • Supply filter: Coarse > 60 % (G4) (option ePM1 60 % (F7))
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Bypass: Manual
  • Casing material: EPP
  • Humidity sensor: Optional
  • CO2 sensor: Optional
Unit of measurement Enave-T 240 P A14
Connected air duct size mm 160
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 168
Unit current A 1.3
Maximum airflow m3/h 313
Sound pressure level LpA at 3 m dB(A) 35
Heat recovery efficiency, max % 79
Heat exchanger type - Counter flow
Heat exchanger material - Enthalpy
Weight kg 16
Extract filter - Coarse > 60 % (G4)
Supply filter - Coarse > 60 % (G4) (option ePM1 60 % (F7))
Transported air temperature (max) °С 45
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Image
Enave-T 240 P A14 - image 1
431 Kb
Datasheet
"VENTS Enave P" product description 12-2023
1.4 Mb
Manual
"VENTS Enave P" user's manual 04-2024 (V278EN-01)
10.09 Mb
Vents Enave-T 240 P A14 - Dimensions
H W L D W1 L1
272 640 930 160 300 627
Other accessories
Name Photo Description
Vents SF 205x200x48 Coarse 90% G4 SF 205x200x48 Coarse 90% G4 Panel filter G4
Vents SF 205x200x48 ePM1 60% F7 SF 205x200x48 ePM1 60% F7 F7 panel filter
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents SH-32 SH-32 The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems
Name Photo Description
Vents SR 160/600 SR 160/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/900 SR 160/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/1200 SR 160/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KRV 160 KRV 160 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions