Vents VUE 300 V2 mini EC A2

Air handling units equipped with an enthalpy cross flow heat exchanger
  • Maximum airflow: 300 m3/h
  • Sound pressure level LpA at 3 m: 33 dB(A)
  • Heat exchanger type: Cross flow
  • Extract filter: G4
  • Supply filter: G4, F8
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Control: Remote Control
  • Casing material: Galvanized steel
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUE 300 V2 mini EC A2
Connected air duct size mm 125
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 165
Unit current A 1.3
Maximum airflow m3/h 300
Sound pressure level LpA at 3 m dB(A) 33
Heat recovery efficiency, max % 79
Heat exchanger type - Cross flow
Heat exchanger material - Polystyrene
Weight kg 32
Extract filter - G4
Supply filter - G4, F8
Transported air temperature (max) °С 60
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 80
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents VUE 300 V2 mini EC A2 53 250 2016
Trademark Vents
Model VUE 300 V2 mini EC A2
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-54.1 A+ -25.4 C -6.3 F
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 58
Maximum flow rate (m3/h) 250
Electric power input (W) 150
Reference flow rate (m3/s) 0.044
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.313
Control typology Manual control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 53
Declared typology RVU BVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
973 436 391
The annual heating saved (AHS) (kWh/a) Cold Average Warm
6969 3563 1611
Datasheet
"VENTS VUT/VUE V2/H2 mini EC" product description 04-2024
1.22 Mb
Manual
"VENTS VUT/VUE 300 V2/H2 mini EC" user's manual 07-2021 (V161EN-03)
9.67 Mb
Manual
"VENTS VUT(VUE) 250 V(H) mini A12 / A1" user's manual 12-2023 (V25EN-06)
8.62 Mb
BIM/CAD models
VUT/VUE mini (EC)
2.22 Mb
Image
VUE 300 V2 mini EC A2 - image 1
408 Kb
Vents VUE 300 V2 mini EC A2 - Dimensions
ØD B H H1 L L1
125 287 447 495 714 776
Name Photo Description
Vents SR 125/600 SR 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/900 SR 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/1200 SR 125/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/600 SRF 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/900 SRF 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/2000 SRF 125/2000 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KOM 125 KOM 125 Spring-loaded backdraft damper for round ducts
Vents KRV 125 KRV 125 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents SH-32 SH-32 The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems
Other accessories
Name Photo Description
Vents SF 240x184x40 G4 SF 240x184x40 G4 Panel filter G4
Vents SF 240x184x40 F8 SF 240x184x40 F8 F8 panel filter