Unit of measurement | VUT 2000 PBE EC A21 | |
Connected air duct size | mm | 315 |
Phases | - | 3 |
Minimum supply voltage | V | 400 |
Maximum supply voltage | V | 400 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 1063 |
Power of electrical reheater | W | 15000 |
Unit current | A | 26.4 |
Maximum airflow | m3/h | 2100 |
Sound pressure level LpA at 3 m | dB(A) | 36 |
Heat recovery efficiency, max | % | 67 |
Heat exchanger type | - | Cross flow |
Heat exchanger material | - | Aluminum |
Weight | kg | 140 |
Extract filter | - | G4 |
Supply filter | - | G4 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 60 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Name | Photo | Description |
---|---|---|
Vents A22 |
![]() |
Control panels for controlling industrial and residential air handling units |
Vents A22 WiFi |
![]() |
Control panels for controlling industrial and residential air handling units |
Vents A25 |
![]() |
Touch screen control panel for controlling industrial and residential air handling units |
Name | Photo | Description |
---|---|---|
Vents HV2 |
![]() |
Humidity sensor |
Vents CO2-1 |
![]() |
CO2 sensors |
Vents CO2-2 |
![]() |
CO2 sensors |
Vents HR-S |
![]() |
Electro-mechanical humidistat |
Name | Photo | Description |
---|---|---|
Vents SH-32 |
![]() |
Hydraulic U-trap to drain condensate from heat exchangers and coolers |
Name | Photo | Description |
---|---|---|
Vents SR 315/600 |
![]() |
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
Vents SR 315/900 |
![]() |
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
Vents SR 315/1200 |
![]() |
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
Name | Photo | Description |
---|---|---|
Vents KOM 315 |
![]() |
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
Vents KRV 315 |
![]() |
Air dampers for automatic air flow control in round ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo TF230 |
![]() |
The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents SF 708x480x48 G4 |
![]() |
Panel filter G4 |
Name | Photo | Description |
---|---|---|
Vents NKP 315-3,0-1 A21 V.2 |
![]() |
Inline heaters for heat exchanger frost protection |
Vents NKP 315-2,0-1 A21 V.2 |
![]() |
Inline heaters for heat exchanger frost protection |